Single Phase Pad Mounted Transformer Up to 34.5 kV

Let Us Show you what sets us apart

Product Overview

Single Phase Pad Mounted Transformer Up to 34.5 kV

single phase pad mounted transformer up to 34.5 kv
Primary Voltage34.5 kV
Secondary Voltage120 / 240 V
Rated capacity100 / 250 kVA
Frequency50 / 60 Hz
Cooling TypeONAN
Insulation MediumMineral Oil

Technical Specifications

ParameterValue
Product TypeSingle-Phase Pad-Mounted Transformer
BrandCTSS
SeriesZGS
Primary Voltage34.5 kV
PhaseSingle-phase
Rated Capacity100 / 250 kVA
Frequency50 / 60 Hz
Secondary Voltage120 / 240 V
BIL95 / 125 / 150 / 200 kV
LFWV30 / 38 / 50 / 70 kV
Vector GroupI-I0
Tapping Range±2 × 2.5%, off-circuit
Winding MaterialCopper
Core StructureShell-form
Cooling TypeONAN
Insulation MediumMineral Oil
HV BushingsUniversal bushing wells
ProtectionBayonet fuse / Current-limiting fuse
EnclosureNEMA 3R
Cabinet ColorGreen / Custom
StandardsANSI C57.12.34, IEEE, NEMA, RUS
standard accessories 修改0916

Protection & Accessories

Reliable Protection System and Flexible Accessories

Our Pad Mounted Transformers are equipped with reliable protection devices and accessories to ensure safe operation in underground distribution systems and utility applications.

Standard Accessories

HV/LV Bushings

Reliable medium voltage connection with excellent insulation performance.

Oil Level Gauge

Easy monitoring of insulating oil level for maintenance.

 

Pressure Relief Device

Improves transformer safety under abnormal conditions.

Drain Valve

Convenient oil draining and maintenance operation.

Tap Changer

Off-circuit Tap Changer (OCTC), ±2 × 2.5%

Nameplate

Provides complete transformer rating and technical information.

other asserssories

Optional Accessories

Temperature Indicator

Monitors transformer operating temperature for reliability.

Remote Monitoring System

Supports smart grid and remote transformer condition monitoring.

Surge Arrester

Protects pad mounted transformers against lightning and voltage surges.

Key Features of Transformers

Key Benefits:

  • Enhanced operator and public safety
  • No exposed high-voltage components
  • Suitable for underground distribution systems
  • Reliable operation in outdoor environments

Key Benefits:

  • Weather-resistant construction
  • Corrosion-resistant surface treatment
  • Secure locking compartment
  • Suitable for public and utility applications

Key Benefits:

  • Space-saving installation
  • Low-profile outdoor design
  • Easy inspection and maintenance
  • Ideal alternative to overhead distribution systems

Available Configurations:

  • Loop feed distribution system
  • Radial feed distribution system
  • Dead-front cable connection
  • Customized MV and LV connection arrangements

Available protection and accessories include:

  • High voltage fuses
  • Current limiting fuses
  • Load break switches
  • Surge arresters
  • Pressure relief devices
  • Temperature monitoring systems

These protection solutions help ensure safe operation under different load and fault conditions.

Key Benefits:

  • Low no-load losses
  • High energy efficiency
  • Excellent thermal performance
  • Long operational lifetime
strict quality control and transformer testing 1

Manufacturing & Testing

Strict Quality Control and Transformer Testing

Every Pad Mounted Transformer undergoes comprehensive testing to ensure high reliability, safety and long service life according to international standards.

Routine Tests

Transformer Ratio Test

Ensures accurate voltage transformation performance.

Winding Resistance Test

Verifies winding quality and electrical performance.

 

No-Load Loss Test

Checks transformer core efficiency and energy performance.

No-Load Loss Test

Confirms transformer rated efficiency under operating conditions.

Impedance Test

Ensures correct electrical characteristics and system compatibility.

Dielectric Test

Verifies insulation strength and operational safety.

special testing

Special Tests

Temperature Rise Test

Validates thermal performance and cooling capability.

Lightning Impulse Test

Tests insulation capability against surge conditions.

Partial Discharge Test

Ensures insulation quality and long-term reliability.

Everything We Do Is At A High Standard

Would you like to start a project with us?

WHAT WE DO

CTSS Transformer Applications and Solutions

We design and manufacture liquid-filled power transformers and distribution transformers for a wide range of applications, including solar power, data centers, industrial facilities, and utility systems. With experienced engineers and advanced manufacturing capabilities, we provide customized transformer solutions and complex winding designs to meet the specific electrical and performance requirements of each project.

Power Utility

Power Utility

Thermal, nuclear, and large hydro power plants — generator step-up (GSU) duty.

images (2)

Solar & Wind Energy

Centralized wind and solar collection stations requiring bulk power step-up.

ctss mining transformer project

Mining

Steel mills, mines, data centers, and other high-power industrial facilities.

for ev charge

EV Charging Station

High-power electrical facilities requiring reliable transformer solutions and flexible configuration.

oil & gas 6.jpg

Oil & Gas

Demanding industrial facilities requiring reliable power supply and robust transformer performance.

bitcoin mining

Telecom & Data Center

High-power data centers requiring reliable transformer solutions for demanding electrical loads.