| High-voltage rated voltage | 10kV / 35kV / 110kV; customizable | Low-voltage rated voltage | Customized for traction / arc furnace loads; typical 2 x 27.5kV |
| Rated capacity | 1MVA – 120MVA | Power Supply Mode | Three-phase to two-phase or two-phase to three-phase power conversion |
| Frequency | 50Hz; 60Hz customizable for overseas projects | Cooling Type | Oil-immersed: ONAN / ONAF / OFAF; dry-type: AN / AF |
| Transformer Type | Scott Connection Transformer | Connection Type | Scott connection with Main Transformer and Teaser Transformer |
| Phase Conversion | Three-phase to two-phase and two-phase to three-phase bidirectional conversion | Two-phase Output | Equal voltage magnitude with 90° electrical phase shift |
| Vector Group | Scott connection, combined Main + Teaser transformer unit | Installation | Indoor / Outdoor |
| Insulation Level | Compliant with IEC 60076 and GB 1094 series standards | Ambient Conditions | -40°C to +40°C; high-altitude, coastal salt-spray and extreme-cold versions available |
| Typical Model | 25MVA, 110kV / 2 x 27.5kV oil-immersed Scott traction transformer | Typical Rated Capacity | 25MVA |
| Typical HV Three-phase Voltage | 110kV | Typical LV Two-phase Voltage | 2 x 27.5kV |
| Typical Phase Shift | 90° between the two-phase outputs | Typical Cooling Arrangement | ONAF oil-immersed forced-air cooling |
| Anti-corrosion Grade | C3, C4, C5, CX-H | Typical Installation | Outdoor traction substation installation |
| Connection Characteristic | Standard Scott connection for balanced three-phase to two-phase conversion | Negative-sequence Mitigation | Designed to reduce negative-sequence current injected into the three-phase grid |
| Partial Discharge Level | <100pC at 1.5 x rated voltage for oil-immersed type; <=10pC at 1.1 x rated voltage for dry-type | Noise Level | <=68dB(A) at 1m; low-noise version available |
| Short-circuit Withstand | Designed according to IEC 60076-5 with multi-physics structural reinforcement | Short-circuit Test | Performed only by specialized accredited third-party testing institutions |
| Thermal Performance | Temperature rise compliant with IEC / GB standards | Thermal Margin | Sufficient thermal margin reserved for unbalanced two-phase loads |
| Design Life | >=30 years under normal operating conditions | Insulation Medium | Mineral oil or high-fire-point ester oil for oil-immersed type; dry-type epoxy encapsulation |
| Oil-free Option | Dry-type epoxy encapsulation with no insulating oil | Fire Safety | Dry-type configuration without oil-related fire or explosion risk |
| Carbon Footprint | LCA life-cycle assessment documentation available upon request | ESG Support | LCA documentation available to support customer ESG reporting |
| Core Material | High-permeability low-loss grain-oriented silicon steel | Core Structure | Independent core structures for Main Transformer and Teaser Transformer |
| Core Joint Control | Strict joint control to reduce no-load loss and noise | Core Clamping | Controlled clamping force for mechanical stability and reduced vibration |
| Core Coating | Insulating anti-corrosion coating | Winding Structure | Main winding and Teaser winding with turns precisely matched according to Scott theory |
| Winding Ratio | Winding turns precisely matched according to Scott connection theory | Conductor Transposition | Transposed conductors to reduce additional eddy losses under unbalanced loads |
| Winding Insulation | High-strength insulation structure designed for frequent two-phase load fluctuations | Oil-immersed Winding Process | Multi-stage vacuum drying and vacuum oil filling |
| Dry-type Winding Process | Epoxy fibreglass vacuum-impregnated encapsulation | Partial Discharge Control | Turn and layer insulation redundancy with strict partial-discharge control |
| Oil Tank | Steel tank with magnetic shielding to reduce tank stray loss | Tank Integrity | 100% weld inspection and positive / negative pressure tightness testing |
| Oil Tank Corrosion Protection | C3, C4, C5, CX-H | Cooling Selection | ONAN / ONAF / OFAF for oil-immersed type; AN / AF for dry-type |
| Bushings | Available as standard auxiliary equipment | Tap-changer | Off-circuit tap changer or OLTC optional |
| Pressure Relief Device | Available for oil-immersed configuration | Buchholz Relay | Optional protection accessory for oil-immersed type |
| Oil Level Indicator | Available for oil-immersed configuration | Winding Temperature Sensor | PT100 winding temperature sensor |
| DGA Monitoring | Dissolved gas analysis online monitoring available as an option | Special Options | Buchholz protection / winding temperature measurement / DGA online monitoring |
| Electromagnetic Design | 3D FEM simulation with Scott connection magnetic circuit modeling | Ampere-turn Balance | Main and Teaser winding ampere-turn balance verification |
| Unbalanced Load Analysis | Stray-loss calculation under unbalanced two-phase load | Negative-sequence Analysis | Evaluation of negative-sequence current on the three-phase side |
| Mechanical / Seismic Design | ANSYS structural simulation for short-circuit electrodynamic force and structural strength | Seismic Qualification | IEEE 693 compliance available for high-seismic-intensity substations |
| Short-circuit Simulation | Transient electromagnetic-field simulation for three-phase-side and two-phase-side short-circuit conditions | Winding Force Analysis | Dynamic electrodynamic force calculation and winding structural verification |
| Insulation Coordination | Electric-field simulation for main and longitudinal insulation | Impulse Withstand | Lightning impulse and switching impulse withstand verification |
| Thermal-flow Simulation | CFD oil-flow / air-convection simulation | Hot-spot Analysis | Hot-spot temperature prediction under steady-state and unbalanced two-phase loads |
| Capacity Ratio Optimization | Simulation-based optimization of Main Transformer and Teaser Transformer capacity ratio | Stray-loss Optimization | Reduction of stray heating caused by unbalanced loads |
| Applicable Standards | IEC 60076-1 / IEC 60076-2 / IEC 60076-3 / IEC 60076-5 | China Standards | GB 1094 series and GB/T 6451 |
| North America Standard | IEEE C57.12.00 optional for export projects | Seismic Standard | IEEE 693 optional for high-seismic-intensity substations |
| Environmental Compliance | RoHS / REACH hazardous-substance control | PCB Requirement | PCB-free insulating liquid requirement according to EPA 40 CFR Part 761 |
| Material Compliance | Key components and insulation materials comply with IEC / GB requirements | Material Traceability | Full material traceability throughout the supply chain |
| Factory Acceptance Test | Routine and type tests including ratio measurement, vector group verification, DC resistance, loss, partial discharge and dielectric withstand | FAT Short-circuit Scope | Short-circuit test excluded from FAT scope |
| Witness Testing | Client or third-party witnessed testing available | Third-party Short-circuit Testing | Specialized accredited third-party laboratory required |
| Site Service | Installation guidance, tanking supervision, core lifting if required and pre-commissioning inspection | Commissioning Support | Technical support for commissioning |
| Warranty | Comprehensive product warranty | Extended Service | Extended service agreement optional |
| Spare Parts Supply | Minimum 25-year spare-parts supply for key components | Training | On-site or remote operation and maintenance training |
| Training Scope | Scott connection principle, unbalanced load characteristics, negative-sequence impact and O&M requirements | Quality Management | ISO 9001 / ISO 14001 / ISO 45001 |
| Customization Capability | Oil-immersed / dry-type design with flexible capacity and voltage combinations | Special Environment Options | High-altitude, salt-spray anti-corrosion, low-noise and online monitoring options |
| Typical Application | Electrified railway traction substations | Railway Function | Three-phase to two-phase conversion for catenary power supply and negative-sequence reduction |
| Metallurgical Application | Two-phase AC electric arc furnace power supply | Industrial Load Application | High-power two-phase industrial loads |
| System Retrofit Application | Legacy two-phase power system renovation | Conversion Function | Bidirectional two-phase to three-phase and three-phase to two-phase conversion |
| Special Test Application | Two-phase orthogonal power test bench | Project Experience | Railway traction and metallurgical arc furnace Scott transformer projects |
| Export Frequency | 60Hz versions available for overseas EPC projects | Technical Documentation | Simulation reports, type-test reports, material certificates and traceability documents |
| Negative-sequence Report | Negative-sequence calculation report available | Technical Support | Early coordination with design institutes for system-level technical evaluation |