| High-voltage rated voltage | 3kV – 110kV; higher voltage available upon custom request | Low-voltage rated voltage | 0.4kV – 3.5kV valve-side voltage; customized for rectifier bridge applications |
| Rated capacity | 500kVA – 50MVA; larger capacity available upon custom design | Power Supply Mode | AC grid input to rectifier stack for high-current DC power supply |
| Frequency | 50Hz / 60Hz; dual-frequency design available | Cooling Type | ONAN / ONAF / OFAF for oil-immersed type; AN / AF for dry-type |
| Transformer Type | Rectifier transformer; oil-immersed or dry-type | Application Type | Industrial rectification and high-current DC power supply |
| Pulse Configuration | 6-pulse / 12-pulse / 24-pulse / 36-pulse multi-phase shift | Short-circuit Impedance | 6% – 20%; adjustable according to rectifier-system short-circuit-current-limiting requirements |
| No-load Current | <0.20% – 0.35% measured at rated voltage | Tap-changer | Off-circuit tap changer standard; on-load OLTC vacuum tap changer optional |
| Insulation Level | According to IEC 60076-3 and GB 1094 series based on voltage grade | Primary Grid-side Voltage | 35kV ±2 x 2.5% in the reference application; custom tap range available |
| Valve-side Voltage | 0.4kV – 3.5kV in the reference application; customized according to rectifier bridge requirements | Typical Model | 25MVA / 35kV 12-pulse oil-immersed rectifier transformer |
| Configuration | 3-phase, multi-secondary split-winding, phase-shift structure | Cooling Arrangement | OFAF forced oil forced air for oil-immersed type; AF forced air cooling for dry-type |
| Phase-shift Accuracy | Multi-pulse winding phase-angle deviation within ±0.5° | Harmonic Adaptability | Designed for non-sinusoidal current and harmonic additional loss conditions |
| Short-circuit Withstand | Designed and validated according to IEC 60076-5 and GB/T 18494; dynamic-force safety margin >1.3 x calculated value | Thermal Performance | Hot-spot temperature rise complies with IEC / GB limits; ≥20% thermal margin for short-time overload |
| Overload Capability | 150% overload for 2 hours; 200% overload for 1 minute; application-specific | Life Expectancy | ≥30 years under normal service conditions and rated rectifier working conditions |
| Partial Discharge Level | Oil-immersed: <100pC at 1.5 x rated voltage; dry-type: compliant with GB 1094.11 requirements | Noise Level | Typical ≤68dB(A) at 1m; low-noise design available down to 60dB(A) |
| Energy Efficiency | No-load and load losses independently verified; harmonic additional loss calculated according to IEC 61378-1 | Harmonic Loss | Additional harmonic loss considered in electromagnetic and thermal design |
| Insulation and Fluid Option | Mineral oil or biodegradable ester fluid for oil-immersed type; F/H-class epoxy casting for dry-type | Insulation Type | Oil-immersed insulation or dry-type epoxy insulation |
| Core Material | High-permeability low-loss grain-oriented silicon steel, M-4 / M-5 grade or equivalent | Core Construction | Five-step stepped-lap construction with fully mitered joints |
| Core Clamping | Optimized clamping structure designed to restrain harmonic magnetic-flux vibration | Core Gap Control | Strict gap control to suppress DC-bias magnetic risk under rectifier operation |
| Winding Structure | Multi-winding / split-winding / phase-shift winding structure customized for 6-, 12-, 24- and 36-pulse systems | Conductor Transposition | Optimized transposition to reduce harmonic eddy-current and circulating-current losses |
| Winding Cooling Design | Oil-duct / air-duct layout optimized for non-uniform harmonic heating | Winding Mechanical Strength | Enhanced mechanical fastening to withstand repeated rectifier-side commutation short-circuit forces |
| Oil-immersed Manufacturing | Full vacuum drying and oil impregnation to control partial-discharge risk | Dry-type Manufacturing | Epoxy vacuum casting with high mechanical strength and resistance to moisture and pollution |
| Tank Stray-loss Suppression | Magnetic shunting and copper shielding composite design | Tank Integrity Test | Full vacuum and positive-pressure integrity testing for oil-immersed tank |
| Corrosion Protection | Anti-corrosion coating up to C5-M grade optional | Protective Enclosure | Optional IP protective enclosure for dry-type units |
| Temperature Monitoring | Built-in PT100 temperature sensor for real-time winding hot-spot monitoring | Special Function | Built-in winding temperature monitoring and harmonic-loss optimized design |
| Electromagnetic Design | 3D finite-element modeling with harmonic eddy-current loss and multi-winding phase-shift simulation | Phase-shift Simulation | 6-pulse / 12-pulse / 24-pulse / 36-pulse rectification system phase-shift angle simulation |
| Mechanical / Seismic Design | ANSYS structural analysis for winding dynamic force and mechanical strength | Seismic Standard | IEEE 693 seismic compliance available as an option |
| Short-circuit Simulation | Transient magnetic-field simulation for winding stress and rectifier commutation peak current | Harmonic Load Simulation | Stray-loss increase caused by harmonic flux evaluated during design |
| Insulation Coordination | Electric-field distribution simulation with DC-component superposition on valve-side winding insulation | Impulse Withstand | Lightning impulse and switching impulse withstand verification |
| Thermal-flow Simulation | CFD oil-flow / air-flow simulation with harmonic additional loss included | Hot-spot Control | Hot-spot temperature prediction with reserved overload temperature margin |
| Applicable Standard | IEC 61378-1 / IEC 61378-3; IEC 60076 series | North America Standard | IEEE C57.18.10 for semiconductor rectifier transformer performance and testing |
| China Standards | GB/T 18494.1-2014 / GB/T 18494.3-2023; GB 1094 series | Dry-type Standard | GB 1094.11 dry-type power transformer technical requirements |
| Industrial Standard | JB/T 8636 technical specification for power converter transformers | Environmental Compliance | RoHS / REACH; PCB-free dielectric fluid requirement according to EPA 40 CFR Part 761 |
| Material Traceability | Critical components sourced from IEC / GB compliant supply chains with full material traceability | Quality Management | ISO 9001 / ISO 14001 / ISO 45001 certified manufacturing site |
| Factory Acceptance Test | Complete routine test, type test and special test | Special Test Items | Harmonic-related assessment and multi-winding phase-shift angle verification |
| Witness Testing | Client or third-party inspection available | Testing Organizations | KEMA, CESI, DNV and domestic authorized testing institutes available |
| Site Service | Installation guidance, commissioning supervision and post-commissioning performance verification | Service Condition | Performance verification can be conducted under actual rectifier load |
| Warranty | Comprehensive product warranty; extended service agreement optional | Spare Parts Supply | Minimum 25-year spare-parts supply support |
| Training | On-site or remote operator and maintenance training | Training Scope | Special operating-mode precautions for rectifier transformers |
| Customization Capability | Multi-pulse phase-shift, oil-immersed / dry-type, anti-corrosion, seismic, high-altitude and tropical-humid adaptations | Environmental Adaptability | Customized solutions for coastal, chemical-plant, high-altitude and special industrial environments |
| Typical Applications | Electrolytic aluminum, electrolytic copper, chlor-alkali, water-electrolysis hydrogen production | Metallurgical Applications | DC electric-arc furnace, rolling mill DC drive and mine hoist rectifier power supply |
| Rail Transit Applications | Subway traction rectifier power-supply systems and 12-pulse / 24-pulse rectifier units | Mining Applications | Mineral processing, electroplating and surface-treatment production lines |
| New-energy Applications | Centralized rectification for renewable-energy power stations | Energy-storage Application | Energy-storage converter front-end transformer |
| Project Experience | Rectifier transformers running in more than 30 countries | Project Scope | Electrolysis, hydrogen production, metallurgy, rail transit and turn-key industrial projects |
| Technical Support | Early-stage technical co-review with rectifier-system suppliers | Loss Calculation | Open-book loss calculation including harmonic additional loss |
| Technical Documentation | Full material documentation and complete test-report delivery | Carbon Footprint | LCA environmental life-cycle assessment data available on request |