Rectifier Transformer

Let Us Show you what sets us apart

Product Overview

Rectifier Transformer

rectifier transformer
High-voltage rated voltage3kV - 110kV; higher voltage available upon custom request
Low-voltage rated voltage0.4kV - 3.5kV valve-side voltage; customized for rectifier bridge applications
Rated capacity500kVA - 50MVA; larger capacity available upon custom design
Power Supply ModeAC grid input to rectifier stack for high-current DC power supply
Frequency50Hz / 60Hz; dual-frequency design available
Cooling TypeONAN / ONAF / OFAF for oil-immersed type; AN / AF for dry-type

Technical Specifications

ParameterValueParameterValue
High-voltage rated voltage3kV – 110kV; higher voltage available upon custom requestLow-voltage rated voltage0.4kV – 3.5kV valve-side voltage; customized for rectifier bridge applications
Rated capacity500kVA – 50MVA; larger capacity available upon custom designPower Supply ModeAC grid input to rectifier stack for high-current DC power supply
Frequency50Hz / 60Hz; dual-frequency design availableCooling TypeONAN / ONAF / OFAF for oil-immersed type; AN / AF for dry-type
Transformer TypeRectifier transformer; oil-immersed or dry-typeApplication TypeIndustrial rectification and high-current DC power supply
Pulse Configuration6-pulse / 12-pulse / 24-pulse / 36-pulse multi-phase shiftShort-circuit Impedance6% – 20%; adjustable according to rectifier-system short-circuit-current-limiting requirements
No-load Current<0.20% – 0.35% measured at rated voltageTap-changerOff-circuit tap changer standard; on-load OLTC vacuum tap changer optional
Insulation LevelAccording to IEC 60076-3 and GB 1094 series based on voltage gradePrimary Grid-side Voltage35kV ±2 x 2.5% in the reference application; custom tap range available
Valve-side Voltage0.4kV – 3.5kV in the reference application; customized according to rectifier bridge requirementsTypical Model25MVA / 35kV 12-pulse oil-immersed rectifier transformer
Configuration3-phase, multi-secondary split-winding, phase-shift structureCooling ArrangementOFAF forced oil forced air for oil-immersed type; AF forced air cooling for dry-type
Phase-shift AccuracyMulti-pulse winding phase-angle deviation within ±0.5°Harmonic AdaptabilityDesigned for non-sinusoidal current and harmonic additional loss conditions
Short-circuit WithstandDesigned and validated according to IEC 60076-5 and GB/T 18494; dynamic-force safety margin >1.3 x calculated valueThermal PerformanceHot-spot temperature rise complies with IEC / GB limits; ≥20% thermal margin for short-time overload
Overload Capability150% overload for 2 hours; 200% overload for 1 minute; application-specificLife Expectancy≥30 years under normal service conditions and rated rectifier working conditions
Partial Discharge LevelOil-immersed: <100pC at 1.5 x rated voltage; dry-type: compliant with GB 1094.11 requirementsNoise LevelTypical ≤68dB(A) at 1m; low-noise design available down to 60dB(A)
Energy EfficiencyNo-load and load losses independently verified; harmonic additional loss calculated according to IEC 61378-1Harmonic LossAdditional harmonic loss considered in electromagnetic and thermal design
Insulation and Fluid OptionMineral oil or biodegradable ester fluid for oil-immersed type; F/H-class epoxy casting for dry-typeInsulation TypeOil-immersed insulation or dry-type epoxy insulation
Core MaterialHigh-permeability low-loss grain-oriented silicon steel, M-4 / M-5 grade or equivalentCore ConstructionFive-step stepped-lap construction with fully mitered joints
Core ClampingOptimized clamping structure designed to restrain harmonic magnetic-flux vibrationCore Gap ControlStrict gap control to suppress DC-bias magnetic risk under rectifier operation
Winding StructureMulti-winding / split-winding / phase-shift winding structure customized for 6-, 12-, 24- and 36-pulse systemsConductor TranspositionOptimized transposition to reduce harmonic eddy-current and circulating-current losses
Winding Cooling DesignOil-duct / air-duct layout optimized for non-uniform harmonic heatingWinding Mechanical StrengthEnhanced mechanical fastening to withstand repeated rectifier-side commutation short-circuit forces
Oil-immersed ManufacturingFull vacuum drying and oil impregnation to control partial-discharge riskDry-type ManufacturingEpoxy vacuum casting with high mechanical strength and resistance to moisture and pollution
Tank Stray-loss SuppressionMagnetic shunting and copper shielding composite designTank Integrity TestFull vacuum and positive-pressure integrity testing for oil-immersed tank
Corrosion ProtectionAnti-corrosion coating up to C5-M grade optionalProtective EnclosureOptional IP protective enclosure for dry-type units
Temperature MonitoringBuilt-in PT100 temperature sensor for real-time winding hot-spot monitoringSpecial FunctionBuilt-in winding temperature monitoring and harmonic-loss optimized design
Electromagnetic Design3D finite-element modeling with harmonic eddy-current loss and multi-winding phase-shift simulationPhase-shift Simulation6-pulse / 12-pulse / 24-pulse / 36-pulse rectification system phase-shift angle simulation
Mechanical / Seismic DesignANSYS structural analysis for winding dynamic force and mechanical strengthSeismic StandardIEEE 693 seismic compliance available as an option
Short-circuit SimulationTransient magnetic-field simulation for winding stress and rectifier commutation peak currentHarmonic Load SimulationStray-loss increase caused by harmonic flux evaluated during design
Insulation CoordinationElectric-field distribution simulation with DC-component superposition on valve-side winding insulationImpulse WithstandLightning impulse and switching impulse withstand verification
Thermal-flow SimulationCFD oil-flow / air-flow simulation with harmonic additional loss includedHot-spot ControlHot-spot temperature prediction with reserved overload temperature margin
Applicable StandardIEC 61378-1 / IEC 61378-3; IEC 60076 seriesNorth America StandardIEEE C57.18.10 for semiconductor rectifier transformer performance and testing
China StandardsGB/T 18494.1-2014 / GB/T 18494.3-2023; GB 1094 seriesDry-type StandardGB 1094.11 dry-type power transformer technical requirements
Industrial StandardJB/T 8636 technical specification for power converter transformersEnvironmental ComplianceRoHS / REACH; PCB-free dielectric fluid requirement according to EPA 40 CFR Part 761
Material TraceabilityCritical components sourced from IEC / GB compliant supply chains with full material traceabilityQuality ManagementISO 9001 / ISO 14001 / ISO 45001 certified manufacturing site
Factory Acceptance TestComplete routine test, type test and special testSpecial Test ItemsHarmonic-related assessment and multi-winding phase-shift angle verification
Witness TestingClient or third-party inspection availableTesting OrganizationsKEMA, CESI, DNV and domestic authorized testing institutes available
Site ServiceInstallation guidance, commissioning supervision and post-commissioning performance verificationService ConditionPerformance verification can be conducted under actual rectifier load
WarrantyComprehensive product warranty; extended service agreement optionalSpare Parts SupplyMinimum 25-year spare-parts supply support
TrainingOn-site or remote operator and maintenance trainingTraining ScopeSpecial operating-mode precautions for rectifier transformers
Customization CapabilityMulti-pulse phase-shift, oil-immersed / dry-type, anti-corrosion, seismic, high-altitude and tropical-humid adaptationsEnvironmental AdaptabilityCustomized solutions for coastal, chemical-plant, high-altitude and special industrial environments
Typical ApplicationsElectrolytic aluminum, electrolytic copper, chlor-alkali, water-electrolysis hydrogen productionMetallurgical ApplicationsDC electric-arc furnace, rolling mill DC drive and mine hoist rectifier power supply
Rail Transit ApplicationsSubway traction rectifier power-supply systems and 12-pulse / 24-pulse rectifier unitsMining ApplicationsMineral processing, electroplating and surface-treatment production lines
New-energy ApplicationsCentralized rectification for renewable-energy power stationsEnergy-storage ApplicationEnergy-storage converter front-end transformer
Project ExperienceRectifier transformers running in more than 30 countriesProject ScopeElectrolysis, hydrogen production, metallurgy, rail transit and turn-key industrial projects
Technical SupportEarly-stage technical co-review with rectifier-system suppliersLoss CalculationOpen-book loss calculation including harmonic additional loss
Technical DocumentationFull material documentation and complete test-report deliveryCarbon FootprintLCA environmental life-cycle assessment data available on request
standard accessories 修改0916

Protection & Accessories

Reliable Protection System and Flexible Accessories

Our Pad Mounted Transformers are equipped with reliable protection devices and accessories to ensure safe operation in underground distribution systems and utility applications.

Standard Accessories

HV/LV Bushings

Reliable medium voltage connection with excellent insulation performance.

Oil Level Gauge

Easy monitoring of insulating oil level for maintenance.

 

Pressure Relief Device

Improves transformer safety under abnormal conditions.

Drain Valve

Convenient oil draining and maintenance operation.

Tap Changer

Off-circuit Tap Changer (OCTC), ±2 × 2.5%

Nameplate

Provides complete transformer rating and technical information.

other asserssories

Optional Accessories

Temperature Indicator

Monitors transformer operating temperature for reliability.

Remote Monitoring System

Supports smart grid and remote transformer condition monitoring.

Surge Arrester

Protects pad mounted transformers against lightning and voltage surges.

Key Features of Transformers

Key Benefits:

  • Enhanced operator and public safety
  • No exposed high-voltage components
  • Suitable for underground distribution systems
  • Reliable operation in outdoor environments

Key Benefits:

  • Weather-resistant construction
  • Corrosion-resistant surface treatment
  • Secure locking compartment
  • Suitable for public and utility applications

Key Benefits:

  • Space-saving installation
  • Low-profile outdoor design
  • Easy inspection and maintenance
  • Ideal alternative to overhead distribution systems

Available Configurations:

  • Loop feed distribution system
  • Radial feed distribution system
  • Dead-front cable connection
  • Customized MV and LV connection arrangements

Available protection and accessories include:

  • High voltage fuses
  • Current limiting fuses
  • Load break switches
  • Surge arresters
  • Pressure relief devices
  • Temperature monitoring systems

These protection solutions help ensure safe operation under different load and fault conditions.

Key Benefits:

  • Low no-load losses
  • High energy efficiency
  • Excellent thermal performance
  • Long operational lifetime
strict quality control and transformer testing 1

Manufacturing & Testing

Strict Quality Control and Transformer Testing

Every Pad Mounted Transformer undergoes comprehensive testing to ensure high reliability, safety and long service life according to international standards.

Routine Tests

Transformer Ratio Test

Ensures accurate voltage transformation performance.

Winding Resistance Test

Verifies winding quality and electrical performance.

 

No-Load Loss Test

Checks transformer core efficiency and energy performance.

No-Load Loss Test

Confirms transformer rated efficiency under operating conditions.

Impedance Test

Ensures correct electrical characteristics and system compatibility.

Dielectric Test

Verifies insulation strength and operational safety.

special testing

Special Tests

Temperature Rise Test

Validates thermal performance and cooling capability.

Lightning Impulse Test

Tests insulation capability against surge conditions.

Partial Discharge Test

Ensures insulation quality and long-term reliability.

Everything We Do Is At A High Standard

Would you like to start a project with us?

WHAT WE DO

CTSS Transformer Applications and Solutions

We design and manufacture liquid-filled power transformers and distribution transformers for a wide range of applications, including solar power, data centers, industrial facilities, and utility systems. With experienced engineers and advanced manufacturing capabilities, we provide customized transformer solutions and complex winding designs to meet the specific electrical and performance requirements of each project.

images (4)

Power Utility

Thermal, nuclear, and large hydro power plants — generator step-up (GSU) duty.

images (2)

Solar & Wind Energy

Centralized wind and solar collection stations requiring bulk power step-up.

usine vue aerienne 04(1)

Mining

Steel mills, mines, data centers, and other high-power industrial facilities.

for ev charge

EV Charging Station

High-power electrical facilities requiring reliable transformer solutions and flexible configuration.

oil & gas 6.jpg

Oil & Gas

Demanding industrial facilities requiring reliable power supply and robust transformer performance.

bitcoin mining

Telecom & Data Center

High-power data centers requiring reliable transformer solutions for demanding electrical loads.