NGR Neutral Grounding Resistor
The NGR Neutral Grounding Resistor System is designed for neutral
grounding applications in medium- and high-voltage power systems.
It is suitable for cable-based urban distribution networks,
industrial facilities, airports, ports, metro systems, power plants,
generator systems, and auxiliary power systems.
Indoor / Outdoor
Configurable Resistance
Multiple Fault Durations
Technical Specifications
| Standard Product Fields | |
|---|---|
| High-voltage Rated Voltage | 0.4 kV–110 kV applicable voltage range; confirm the system-specific rated voltage. |
| Low-voltage Rated Voltage | Resistor rating unspecified; confirm optional grounding transformer. |
| Rated Capacity | Project-specific; Not specified; subject to confirmation. |
| Power Supply Mode | Neutral grounding resistor system. |
| Frequency | Not specified; confirm with the manufacturer. |
| Cooling Type | Airflow-based heat dissipation through the resistor enclosure; confirm the final configuration. |
| Insulation Medium | Air insulation for the resistor assembly; confirm the final design |
| Electrical and Installation Data | |
| Applicable Voltage | 0.4 kV–110 kV |
| Allowable Current | Selectable according to project requirements. |
| Nominal Resistance | Selectable according to project requirements. |
| Fault Duration / Operating Duty | 10 s, 30 s, 60 s, 10 min, or continuous operation. |
| Installation Location | Indoor or outdoor. |
| Line Entry / Exit | Top-in/bottom-out, bottom-in/bottom-out, side-in/side-out, or side-in/bottom-out. |
| Zero-sequence Current Transformer | Optional, according to customer requirements. |
| Resistor Element Maximum Operating Temperature | Up to 1000°C, as stated in the supplied description. |
| Ambient Temperature | −35°C to +50°C. |
| Altitude | Generally not exceeding 1000 m. |
| Seismic Intensity | Not exceeding level 8, as stated in the source. |
| Maximum Ice Thickness | 15 mm. |
| Pollution Level | Up to level IV, as stated in the source. |
selected according to the actual power-system grounding design.
The applicable voltage range is not a substitute for a project-specific
nameplate rating.
Resistor Construction and Materials
The supplied product description identifies nickel-chromium alloy
and specially formulated stainless-steel alloy as resistor element
materials. The final material depends on the selected configuration.
High-Temperature Resistance
The source states a melting-point range of 1375–1500°C and a
maximum operating temperature of 1000°C for the resistor element.
Mechanical Strength
The supplied description states a tensile strength of 700 MPa
and reports that mechanical strength is largely maintained at
temperatures of 900–1000°C.
Resistance Stability
The source describes high-resistivity alloy material and low
temperature-related resistance variation to support stable
protective performance.
Modular Construction
Multiple resistor element designs are available. Standard
modules can be connected in series or parallel to meet
project-specific voltage, resistance, and current requirements.
Optional Components
- Dry-type grounding transformer with epoxy-resin casting, where configured.
- Zero-sequence current transformer.
- Single-phase isolating switch.
- Online resistor monitoring device.
- Heater and temperature-humidity controller.
Optional components and system arrangements should be confirmed
against the customer’s wiring scheme and technical requirements.
Product Features
- Flexible configurations: suitable configurations for distribution networks and generator neutral grounding applications.
- Selectable electrical parameters: allowable current and nominal resistance can be specified for each project.
- Modular resistor elements: series and parallel combinations support different electrical requirements.
- Heat dissipation design: enclosure airflow passages help manage heat during operation.
- Optional monitoring: online monitoring and environmental-control accessories can be specified.
- Service-life statement: the supplied description states a 30-year service-life commitment and reports some in-service units exceeding 50 years.
Applications
Utility Distribution Networks
Urban cable distribution networks and other distribution-system grounding applications.
Industrial Facilities
Large industrial and mining enterprises with project-specific neutral grounding requirements.
Infrastructure
Airports, seaports, metro systems, and other important electrical users.
Power Generation
Generator neutral grounding and power-plant auxiliary power systems.
Available product types include low-resistance and high-resistance
grounding systems for distribution networks, as well as high-resistance
grounding systems for generator neutrals.
Standards Listed in the Product Description
- DL/T 780-2001 — Neutral Grounding Resistors for Distribution Systems
- GB 6450 — Dry-Type Power Transformers
- DL/T 620-1997 — Overvoltage Protection and Insulation Coordination for AC Electrical Installations
- GB/T 16927-1997 — High-Voltage Test Techniques
- GB 1208-1997 — Current Transformers
- GB 4208-1993 — Degrees of Protection Provided by Enclosures (IP Code)
- IEEE 32-1972 — Requirements, Terminology, and Test Procedures for Neutral Grounding Devices
- GB 311.1-1997 — Insulation Coordination for High-Voltage Transmission and Distribution Equipment
- DL/T 593-1996 — Common Technical Specifications for High-Voltage Switchgear
- GB/T 11022-1999 — Common Specifications for High-Voltage Switchgear and Controlgear
Confirm current editions and project-specific compliance requirements
with the manufacturer before procurement.
Need an NGR Solution for Your Project?
Share your system voltage, required ground-fault current, fault
duration, installation environment, and accessory requirements
to request a project-specific configuration.