Ground Mounted Transformer

Let Us Show you what sets us apart

Product Overview

Ground Mounted Transformer

ground mounted transformer tr
High-voltage rated voltage6kV / 10kV / 20kV / 35kV
Low-voltage rated voltage0.4kV / 0.48kV / 0.69kV
Rated capacity10kVA - 5000kVA
Power Supply ModeNot specified
Frequency50Hz / 60Hz, 60Hz standard for South America
Cooling TypeOil-immersed: ONAN/ONAF; Dry-type: AN/AF

Technical Specifications

High-voltage rated voltage6kV / 10kV / 20kV / 35kVLow-voltage rated voltage0.4kV / 0.48kV / 0.69kV
Rated capacity10kVA – 5000kVAPower Supply ModeNot specified
Frequency50Hz / 60Hz, 60Hz standard for South AmericaCooling TypeOil-immersed: ONAN/ONAF; Dry-type: AN/AF
Vector GroupDyn11 / Yyn0, Dyn11 preferred for exportShort-circuit Impedance4% / 4.5% / 6% / 7.5%, customized per grid coordination
Anti-corrosion GradeC3, C4, C5, CX-HAmbient Adaptation-40°C to +55°C, high-temperature enhanced version, high altitude, salt spray and UV resistant customization
Transformer TypeOil-immersed type / Dry-typeVoltage Range10kV – 35kV series
Maximum Voltage Class35kVMaximum Capacity5000kVA
Applicable StandardsIEC 60076 Series / GB 1094 Series / GB/T 6451 / GB/T 10228North American StandardsANSI C57.12.00 / ANSI C57.12.90
Seismic StandardIEEE 693, optional for seismic zone projectsEnvironmental ComplianceRoHS / REACH / EPA 40 CFR Part 761
Insulation DesignHigh insulation margin, increased creepage distance, anti-condensation and moisture resistant designUV ResistanceUV aging resistant design for strong UV environments
Salt Spray ResistanceSalt spray resistant design, suitable for coastal environmentsTemperature Adaptation-40°C to +55°C high-temperature enhanced version available
Altitude AdaptationHigh altitude customization availableCorrosion ProtectionC3, C4, C5, CX-H
Core MaterialHigh-permeability low-loss grain-oriented silicon steelCore Joint Technology5-step step-lap mitered joint technology
Core ClampingIntegral core clamping structureConductor MaterialHigh-purity copper or aluminum
Winding StructureMulti-strand transposition structureInsulation MaterialHigh-temperature resistant insulation materials
Drying ProcessMulti-stage vacuum dryingImpregnation ProcessVacuum oil impregnation or vacuum varnish impregnation
Partial Discharge ControlStrict partial discharge controlTank ConstructionIntegral welded tank for oil-immersed type
Tank TestingNon-destructive testing and positive/negative pressure tightness testingEnclosure OptionsStainless steel enclosure and heavy anti-corrosion structure optional
Weather ProtectionWeather-resistant coating for strong UV, high temperature and rain exposureProtection StructureRainproof and dustproof structure available
Design Simulation3D multi-physics coupling simulationElectromagnetic OptimizationMagnetic circuit optimization and additional loss reduction
Thermal DesignEnhanced heat dissipation margin for tropical high-temperature environmentsStructural DesignReinforced core clamping structure for transportation vibration and seismic loads
Typical ApplicationsPower grid distribution, industrial parks, commercial complexes, PV and wind power stationsIndustrial ApplicationsMines, oilfields, ports and industrial power distribution systems
Residential ApplicationsResidential areas, schools, hospitals and civil power supply projectsExport ApplicationsSouth America EPC power engineering projects
FAT TestingRoutine and type tests including insulation, ratio, vector group, DC resistance, no-load loss, load loss and temperature riseWithstand TestingPower frequency withstand voltage and induced withstand voltage testing
Partial Discharge TestIncluded in factory acceptance testingShort-circuit TestExcluded from factory FAT, destructive special type test by authorized third-party institutions
Test DocumentationEnglish test reports, material certificates and traceability documents availableEnvironmental DocumentationLCA and ESG lifecycle reports available
Installation SupportOverseas installation guidanceCommissioning SupportRemote commissioning training
WarrantyLong-term warranty availableSpare Parts Supply25-year key spare parts supply guarantee
standard accessories 修改0916

Protection & Accessories

Reliable Protection System and Flexible Accessories

Our Pad Mounted Transformers are equipped with reliable protection devices and accessories to ensure safe operation in underground distribution systems and utility applications.

Standard Accessories

HV/LV Bushings

Reliable medium voltage connection with excellent insulation performance.

Oil Level Gauge

Easy monitoring of insulating oil level for maintenance.

 

Pressure Relief Device

Improves transformer safety under abnormal conditions.

Drain Valve

Convenient oil draining and maintenance operation.

Tap Changer

Off-circuit Tap Changer (OCTC), ±2 × 2.5%

Nameplate

Provides complete transformer rating and technical information.

other asserssories

Optional Accessories

Temperature Indicator

Monitors transformer operating temperature for reliability.

Remote Monitoring System

Supports smart grid and remote transformer condition monitoring.

Surge Arrester

Protects pad mounted transformers against lightning and voltage surges.

Key Features of Transformers

Key Benefits:

  • Enhanced operator and public safety
  • No exposed high-voltage components
  • Suitable for underground distribution systems
  • Reliable operation in outdoor environments

Key Benefits:

  • Weather-resistant construction
  • Corrosion-resistant surface treatment
  • Secure locking compartment
  • Suitable for public and utility applications

Key Benefits:

  • Space-saving installation
  • Low-profile outdoor design
  • Easy inspection and maintenance
  • Ideal alternative to overhead distribution systems

Available Configurations:

  • Loop feed distribution system
  • Radial feed distribution system
  • Dead-front cable connection
  • Customized MV and LV connection arrangements

Available protection and accessories include:

  • High voltage fuses
  • Current limiting fuses
  • Load break switches
  • Surge arresters
  • Pressure relief devices
  • Temperature monitoring systems

These protection solutions help ensure safe operation under different load and fault conditions.

Key Benefits:

  • Low no-load losses
  • High energy efficiency
  • Excellent thermal performance
  • Long operational lifetime
strict quality control and transformer testing 1

Manufacturing & Testing

Strict Quality Control and Transformer Testing

Every Pad Mounted Transformer undergoes comprehensive testing to ensure high reliability, safety and long service life according to international standards.

Routine Tests

Transformer Ratio Test

Ensures accurate voltage transformation performance.

Winding Resistance Test

Verifies winding quality and electrical performance.

 

No-Load Loss Test

Checks transformer core efficiency and energy performance.

No-Load Loss Test

Confirms transformer rated efficiency under operating conditions.

Impedance Test

Ensures correct electrical characteristics and system compatibility.

Dielectric Test

Verifies insulation strength and operational safety.

special testing

Special Tests

Temperature Rise Test

Validates thermal performance and cooling capability.

Lightning Impulse Test

Tests insulation capability against surge conditions.

Partial Discharge Test

Ensures insulation quality and long-term reliability.

Everything We Do Is At A High Standard

Would you like to start a project with us?

WHAT WE DO

CTSS Transformer Applications and Solutions

We design and manufacture liquid-filled power transformers and distribution transformers for a wide range of applications, including solar power, data centers, industrial facilities, and utility systems. With experienced engineers and advanced manufacturing capabilities, we provide customized transformer solutions and complex winding designs to meet the specific electrical and performance requirements of each project.

images (4)

Power Utility

Thermal, nuclear, and large hydro power plants — generator step-up (GSU) duty.

images (2)

Solar & Wind Energy

Centralized wind and solar collection stations requiring bulk power step-up.

usine vue aerienne 04(1)

Mining

Steel mills, mines, data centers, and other high-power industrial facilities.

for ev charge

EV Charging Station

High-power electrical facilities requiring reliable transformer solutions and flexible configuration.

oil & gas 6.jpg

Oil & Gas

Demanding industrial facilities requiring reliable power supply and robust transformer performance.

bitcoin mining

Telecom & Data Center

High-power data centers requiring reliable transformer solutions for demanding electrical loads.