Generator Transformer

Let Us Show you what sets us apart

Product Overview

Generator Transformer

generator transformer 834.1.1 tr
High-voltage rated voltage110kV / 220kV / 330kV / 500kV, customizable
Low-voltage rated voltage10.5kV - 27kV, typical; custom voltages available
Rated capacity30MVA - 800MVA; larger-capacity units customizable
Power Supply ModeGenerator-connected, generator terminal connection
Frequency50Hz; 60Hz customizable for overseas projects
Cooling TypeONAF / OFAF / ODAP forced-oil-circulation cooling

Technical Specifications

High-voltage rated voltage110kV / 220kV / 330kV / 500kV, customizableLow-voltage rated voltage10.5kV – 27kV, typical; custom voltages available
Rated capacity30MVA – 800MVA; larger-capacity units customizablePower Supply ModeGenerator-connected, generator terminal connection
Frequency50Hz; 60Hz customizable for overseas projectsCooling TypeONAF / OFAF / ODAP forced-oil-circulation cooling
Vector GroupYNd11, YNd and other custom configurationsShort-circuit ImpedanceCustom-designed according to power-plant system-protection coordination requirements
No-load Current<0.25% – 0.50%, measured at rated voltageTap-changerOff-circuit tap-changer standard; OLTC optional
Insulation LevelCompliant with IEC 60076-3 and GB 1094 seriesAmbient Conditions-40°C to +40°C; high-altitude, coastal anti-corrosion and extreme-cold versions customizable
Transformer TypeGenerator step-up transformer, oil-immersed power transformerTypical Model240MVA, 220kV / 15.75kV generator step-up transformer
Generator-side Voltage15.75kV in typical application profileGrid-side Voltage220kV in typical application profile
Typical Cooling ArrangementONAF oil-natural-air-forced coolingAnti-corrosion GradeC3, C4, C5, CX-H
Partial-discharge Level<100pC at 1.5 x rated voltageNoise LevelTypical ≤68dB(A) at 1m; low-noise version available
Short-circuit WithstandDesigned and structurally reinforced according to IEC 60076-5; winding dynamic-force safety margin >1.3 x calculated valuesThermal PerformanceTemperature rise compliant with IEC / GB standards; thermal margin reserved for cyclic variable generator loads
Over-excitation CapabilityEnhanced design for generator-unit over-excitation transient eventsDesign Life≥30 years under normal power-plant operating conditions
Insulation & FluidMineral insulating oil; high-fire-point biodegradable ester fluid optionalDielectric FluidMineral oil or high-fire-point biodegradable ester fluid
Tank ConstructionConservator-equipped or fully-sealed tank constructionTank Tightness TestPositive-pressure and negative-pressure tightness testing
Tank Weld InspectionAll tank welds inspected and testedCore MaterialHigh-permeability low-loss grain-oriented silicon steel
Core Joint TechnologyFive-step stepped-lap fully-mitered-joint constructionCore ClampingReinforced core-clamping structure
ConductorAdvanced conductor transposition schemeWinding StructureOptimized winding structure with enhanced mechanical clamping
Winding InsulationUpgraded main-and-minor insulation system for transient over-voltage conditionsDrying ProcessMulti-stage vacuum drying
Impregnation ProcessHot-oil impregnationPartial-discharge ControlStrict partial-discharge control during manufacturing
Bushing AssemblyHigh-reliability bushing assemblyPressure ReliefPressure-relief valve
Oil-level MonitoringOil-level indicatorGas ProtectionGas-relay protection
Winding Temperature MonitoringPT100 winding temperature sensorsDGA MonitoringDGA dissolved-gas-in-oil online monitoring system optional
Electromagnetic Design3D finite-element modelling with stray-loss and additional-loss analysisMechanical DesignANSYS structural simulation and dynamic-force verification
Short-circuit SimulationTransient magnetic-field simulation for winding stress, deformation and clamping-system performanceInsulation CoordinationElectric-field-distribution simulation with lightning-impulse and switching-impulse verification
Thermal-flow SimulationCFD oil-flow simulation and cyclic hot-spot-temperature predictionSeismic DesignSeismic and mechanical-strength verification; IEEE 693 optional
Over-excitation DesignMagnetic-density control and over-excitation capability verificationGenerator-side AdaptabilityDesigned for frequent load fluctuation, unit start-stop inrush current and over-excitation conditions
Generator-side Short-circuit AdaptabilityEnhanced winding mechanical strength for generator-source short-circuit conditionsHarmonic AdaptabilityDesigned to reduce additional losses caused by harmonic currents and leakage flux
Applicable StandardIEC 60076-1 / 2 / 3 / 5Application GuideIEC 60076-8
Chinese StandardGB 1094 seriesTechnical StandardGB/T 6451
North American StandardIEEE C57.12.00 / C57.12.90Seismic StandardIEEE 693 optional for high-seismic-zone power plants
Environmental ComplianceRoHS / REACHDielectric Fluid ComplianceEPA 40 CFR Part 761; PCB-free dielectric fluid
Oil SystemConservator-equipped or fully-sealed configurationCooling ConfigurationONAF / OFAF / ODAP for large-capacity GSU units
Tap-changer ConfigurationOff-circuit tap-changer or OLTC according to power-plant requirementsSpecial OptionsDGA online monitoring system and high-fire-point dielectric fluid
Coastal AdaptationC5-M heavy-duty anti-corrosion coating optionalHigh-altitude AdaptationCustom design available
Extreme-cold AdaptationCustom versions available for extreme-cold power-plant sitesHigh-temperature AdaptationThermal margin optimized for cyclic variable generator-load conditions
Factory Acceptance TestingInsulation test, partial-discharge test, temperature-rise test, noise-level test, ratio test and impedance measurementWitness TestingClient or third-party witnessed testing available
Short-circuit TestSpecial destructive type test performed by authorized third-party institutionsTest DocumentationFull type-test reports, simulation reports, component certificates and material traceability documents
Installation SupportInstallation guidance and commissioning supervisionCommissioning SupportPost-commissioning performance verification under actual generator-loaded conditions
WarrantyComprehensive product warranty; extended service agreement optionalSpare Parts SupplyMinimum 25-year spare-parts supply for key components
TrainingOn-site or remote operation and maintenance trainingQuality ManagementISO 9001 / ISO 14001 / ISO 45001 certified manufacturing facilities
Typical ApplicationCoal-fired power plants and gas combined-cycle power plantsHydro ApplicationHydro-power and pumped-storage power stations
Renewable Energy ApplicationLarge-scale centralized new-energy power-generation basesEPC ApplicationOverseas thermal, hydro and combined-cycle power-plant EPC projects
standard accessories 修改0916

Protection & Accessories

Reliable Protection System and Flexible Accessories

Our Pad Mounted Transformers are equipped with reliable protection devices and accessories to ensure safe operation in underground distribution systems and utility applications.

Standard Accessories

HV/LV Bushings

Reliable medium voltage connection with excellent insulation performance.

Oil Level Gauge

Easy monitoring of insulating oil level for maintenance.

 

Pressure Relief Device

Improves transformer safety under abnormal conditions.

Drain Valve

Convenient oil draining and maintenance operation.

Tap Changer

Off-circuit Tap Changer (OCTC), ±2 × 2.5%

Nameplate

Provides complete transformer rating and technical information.

other asserssories

Optional Accessories

Temperature Indicator

Monitors transformer operating temperature for reliability.

Remote Monitoring System

Supports smart grid and remote transformer condition monitoring.

Surge Arrester

Protects pad mounted transformers against lightning and voltage surges.

Key Features of Transformers

Key Benefits:

  • Enhanced operator and public safety
  • No exposed high-voltage components
  • Suitable for underground distribution systems
  • Reliable operation in outdoor environments

Key Benefits:

  • Weather-resistant construction
  • Corrosion-resistant surface treatment
  • Secure locking compartment
  • Suitable for public and utility applications

Key Benefits:

  • Space-saving installation
  • Low-profile outdoor design
  • Easy inspection and maintenance
  • Ideal alternative to overhead distribution systems

Available Configurations:

  • Loop feed distribution system
  • Radial feed distribution system
  • Dead-front cable connection
  • Customized MV and LV connection arrangements

Available protection and accessories include:

  • High voltage fuses
  • Current limiting fuses
  • Load break switches
  • Surge arresters
  • Pressure relief devices
  • Temperature monitoring systems

These protection solutions help ensure safe operation under different load and fault conditions.

Key Benefits:

  • Low no-load losses
  • High energy efficiency
  • Excellent thermal performance
  • Long operational lifetime
strict quality control and transformer testing 1

Manufacturing & Testing

Strict Quality Control and Transformer Testing

Every Pad Mounted Transformer undergoes comprehensive testing to ensure high reliability, safety and long service life according to international standards.

Routine Tests

Transformer Ratio Test

Ensures accurate voltage transformation performance.

Winding Resistance Test

Verifies winding quality and electrical performance.

 

No-Load Loss Test

Checks transformer core efficiency and energy performance.

No-Load Loss Test

Confirms transformer rated efficiency under operating conditions.

Impedance Test

Ensures correct electrical characteristics and system compatibility.

Dielectric Test

Verifies insulation strength and operational safety.

special testing

Special Tests

Temperature Rise Test

Validates thermal performance and cooling capability.

Lightning Impulse Test

Tests insulation capability against surge conditions.

Partial Discharge Test

Ensures insulation quality and long-term reliability.

Everything We Do Is At A High Standard

Would you like to start a project with us?

WHAT WE DO

CTSS Transformer Applications and Solutions

We design and manufacture liquid-filled power transformers and distribution transformers for a wide range of applications, including solar power, data centers, industrial facilities, and utility systems. With experienced engineers and advanced manufacturing capabilities, we provide customized transformer solutions and complex winding designs to meet the specific electrical and performance requirements of each project.

images (4)

Power Utility

Thermal, nuclear, and large hydro power plants — generator step-up (GSU) duty.

images (2)

Solar & Wind Energy

Centralized wind and solar collection stations requiring bulk power step-up.

usine vue aerienne 04(1)

Mining

Steel mills, mines, data centers, and other high-power industrial facilities.

for ev charge

EV Charging Station

High-power electrical facilities requiring reliable transformer solutions and flexible configuration.

oil & gas 6.jpg

Oil & Gas

Demanding industrial facilities requiring reliable power supply and robust transformer performance.

bitcoin mining

Telecom & Data Center

High-power data centers requiring reliable transformer solutions for demanding electrical loads.