Product Overview
SF6 Circuit Breaker 35kV-550Kv
35 kV SF6 Circuit Breaker 35kV-550Kv
| Rated Voltage | 35 kV |
|---|---|
| Rated Current | 1600 / 2000 A |
| Rated Breaking Current | 20 / 25 / 25 / 31.5 kA |
| Frequency | 50 Hz |
| Insulation Medium | SF₆ Gas |
SF6 Circuit Breaker Overview
An SF6 circuit breaker is a high-voltage switching device used to make and break electrical circuits under specified operating conditions. It is designed to interrupt fault currents within its rated breaking capacity and support the protection and operation of high-voltage power systems.
Using sulfur hexafluoride (SF6) gas as the insulating and arc-quenching medium, an SF6 circuit breaker is commonly applied in high-voltage substations and power transmission networks. Its operating mechanism, control system, and auxiliary components are selected according to the product design and project specifications.
Available configurations and ratings depend on the selected model and applicable technical requirements.
High-Voltage SF6 Circuit Breaker for Power Transmission and Substations
Our SF6 circuit breakers are designed for high-voltage power system applications, providing switching and fault-current interruption within the specified operating ratings. Product configurations can be selected according to system voltage, rated current, short-circuit breaking capacity, and project requirements.
High-voltage switching applications
Model-specific electrical ratings
Configurations tailored to project requirements
Key Features
Reliable Switching Performance
Designed to perform switching operations and interrupt fault currents within the specified electrical ratings.
SF6 Insulation and Arc Quenching
Uses SF6 gas for insulation and arc interruption in accordance with the selected circuit breaker design.
Flexible Operating Configurations
Operating mechanisms, control arrangements, and auxiliary functions depend on the selected model.
Project-Specific Technical Support
Technical documentation and configuration details can be reviewed according to the application and project requirements.

SF6 Circuit Breaker 35kV-550Kv Technical Specifications
LW8-35 Technical Specifications
| Technical Parameter | Specification |
|---|---|
| Product Type | Outdoor SF₆ Circuit Breaker |
| Model | LW8-35 |
| Rated Voltage | 35 kV |
| Maximum Voltage | 40.5 kV |
| Rated Current | 1600 / 2000 A |
| Rated Breaking Current | 20 / 25 / 25 / 31.5 kA |
| Frequency | 50 Hz |
| Insulation Medium | SF₆ Gas |
| Rated Short-Circuit Making Current (Peak) | 50 / 63 / 63 / 80 kA |
| Rated Short-Time Withstand Current | 20 / 25 / 25 / 31.5 kA |
| Rated Peak Withstand Current | 50 / 63 / 63 / 80 kA |
| Rated Out-of-Phase Breaking Current | 5 / 6.3 / 6.3 / 8 kA |
| Rated Short-Circuit Duration | 4 s |
| Rated Switching Single Capacitor Bank Current | 400 A |
| Rated SF₆ Pressure (20°C) | 0.40 / 0.50 MPa |
| Lockout Pressure (20°C) | 0.30 / 0.40 MPa |
| Minimum Operating Temperature | -40 / -30 °C |
| Mechanical Endurance | 5000 operations |
| Closing Time | 0.1 s |
| Opening Time | 0.06 s |
| Operating Mechanism | Spring Operating Mechanism |
| Control Voltage | DC 220 V / DC 110 V / AC 220 V |
Product Structure & Accessories

The SF6 circuit breaker consists of electrical, mechanical, and control components designed to perform switching and fault-current interruption functions. The component arrangement and accessory supply scope depend on the selected model.
Main Components
Interrupter Assembly: Performs the circuit switching and arc-interruption function.
Operating Mechanism: Provides the mechanical energy required for opening and closing operations.
Insulating Components: Provide the required electrical insulation according to the equipment design.
Main Circuit Terminals: Provide electrical connection interfaces.
Control and Auxiliary Circuits: Support operating commands, status indication, and auxiliary functions as specified.
Optional Accessories
Depending on the product design and project requirements, available options may include:
Gas density monitoring device
Gas filling and servicing connections
Local control cabinet or control unit
Auxiliary contacts and position indication components
Mounting and connection accessories
The final component list and accessory configuration should be confirmed against the product drawings, technical specifications, and agreed supply scope.
Working Principle of an SF6 Circuit Breaker 35kV-550Kv
An SF6 circuit breaker operates through a controlled opening and closing mechanism. During a switching operation, the contacts move according to the interrupter design. When the contacts separate, an arc forms and is extinguished by the designed arc-quenching system using SF6 gas.
The circuit breaker is engineered to interrupt currents within its rated operating conditions, including specified fault-current levels. The operating mechanism and control circuits coordinate the opening and closing operations according to the protection and control system.
Actual operating sequences and interruption performance depend on the selected model and its approved technical specifications.
Why Choose Our SF6 Circuit Breaker 35kV-550Kv
Product Configuration Support
We help customers identify suitable circuit breaker configurations based on rated voltage, rated current, short-circuit requirements, and installation conditions.
Technical Documentation
Product specifications, drawings, and supporting documents can be provided according to the selected model and project requirements.
Application-Based Selection
Our team can review the intended application and technical requirements to help determine a suitable product configuration.
Project Communication
We work with customers to clarify technical specifications, accessory requirements, and documentation needs before order confirmation.
Everything We Do Is At A High Standard
Would you like to start a project with us?
WHAT WE DO
Applications
Our high-voltage electrical equipment supports a wide range of power infrastructure projects, from substations and transmission networks to power generation and industrial electrical systems. Equipment selection and configuration depend on the specific application, system requirements, and technical ratings.

Designed for integration into high-voltage substation infrastructure, supporting power system operation and electrical equipment arrangements.

Suitable for high-voltage transmission infrastructure, supporting network operation and the integration of electrical equipment.

Applicable to power plant switchyards and grid connection infrastructure, subject to equipment specifications and project requirements.

Suitable for industrial substations and power infrastructure where high-voltage electrical equipment is required.