| High-voltage rated voltage | 6kV – 35kV | Low-voltage rated voltage | 0.4kV; export versions customizable to 400V, 480V and other voltages |
| Rated capacity | 100kVA – 25000kVA | Power Supply Mode | Three-phase AC power distribution; customized for rectifier and special-purpose applications |
| Frequency | 50Hz; 60Hz customizable for overseas projects | Cooling Type | AN natural-air cooling / AF forced-air cooling |
| Product Series | SCB / SGB / SCBH series dry-type transformers | Transformer Type | Epoxy-cast / VPI dry-type transformer; amorphous-alloy option available |
| Vector Group | Dyn11 / Yyn0 / Ddyn and other configurations customizable | Tap-changer | Off-circuit tap-changer ±2 x 2.5%; on-load tap-changer optional |
| Insulation Class | F-class / H-class optional | Insulation Level | Compliant with IEC 60076-11 and GB/T 1094.11 |
| Enclosure Protection | IP20 standard; IP23 optional | Ambient Conditions | -25°C ~ +40°C; C2/E2/F1 grades customizable for high-altitude, high-temperature and high-humidity environments |
| Core Material | High-permeability low-loss grain-oriented silicon steel; amorphous-alloy option for SCBH series | Core Construction | Five-step stepped-lap fully-mitered-joint construction |
| Winding Technology | Vacuum epoxy resin cast windings; VPI vacuum-pressure-impregnated type optional | Winding Structure | Foil-wound or disc-type structures optional; conductor transposition available |
| Winding Insulation | Epoxy resin cast insulation or NOMEX insulation system for special applications | Environmental Protection | Moisture-proof, dust-proof and pollution-resistant dry-type construction |
| Fire Safety | Oil-free construction; C2 climate, E2 environmental and F1 fire-safety classification achievable | Fire Risk | No insulating oil; no oil leakage or oil-related fire risk |
| Partial Discharge | <= 10pC at 1.5 x rated voltage | Noise Level | Typical <= 62dB(A) at 1m; low-noise version available |
| Short-Circuit Withstand | Designed and validated per IEC 60076-5; winding dynamic-force safety margin > 1.3 x calculated values | Thermal Performance | Temperature rise compliant with IEC/GB standards; >= 20% thermal margin reserved for harmonic-load applications |
| Overload Capability | AF forced-air cooling can increase overload capacity by approximately 40% – 50% | Life Expectancy | >= 30 years under normal operating conditions |
| Temperature Control | Embedded PT100 winding temperature sensors and intelligent temperature controller | Temperature Controller Functions | Fan start/stop; over-temperature alarm; over-temperature trip output |
| Anti-Corrosion Grade | C3, C4, C5, CX-H | Cooling Configuration | AN natural-air cooling / AF forced-air cooling |
| Design Method | Electromagnetic-thermal-flow-mechanical multi-physics coupled design | Electromagnetic Simulation | 3D finite-element modelling; core-winding loss simulation; harmonic additional-loss calculation; electric-field verification |
| Mechanical Simulation | ANSYS structural simulation; winding electromagnetic-force verification; active-part and enclosure strength checks | Short-Circuit Simulation | Transient magnetic-field simulation; winding stress and deformation evaluation |
| Insulation Coordination | HV/LV winding electric-field simulation; lightning-impulse and switching-impulse withstand verification | Thermal-Flow Simulation | CFD airflow simulation; AN/AF airflow-path optimization; hot-spot temperature prediction |
| Seismic Qualification | IEEE 693 compliance available as an option for high-seismic-zone projects | Environmental Classification | C2 low-temperature / E2 high-humidity and polluted-environment operation; F1 fire classification |
| Typical Model | SCB14-10/0.4-1600kVA F-class epoxy-cast dry-type transformer | Reference Configuration | Epoxy-cast windings; dual-mode AN/AF cooling; intelligent temperature controller with fans; IP20 enclosure |
| Reference Primary Voltage | 10kV | Reference Secondary Voltage | 0.4kV |
| Reference Vector Group | Dyn11 | Reference Insulation Class | F-class |
| Special Options | Over-temperature alarm and trip output; online partial-discharge monitoring | Optional Accessories | Enclosure; cooling fans; temperature indicator; live-part indicator; earthing switch; online partial-discharge monitoring module |
| Applicable Standards | IEC 60076-11; IEC 60076-1/2/3/5; GB/T 1094.11-2022; GB/T 10228-2023; GB 20052; GB/T 17211 | Export Standards | IEEE C57.12.91 optional; IEEE 693 optional; RoHS and REACH |
| Energy Efficiency | SCB conventional silicon-steel series; SCBH amorphous-alloy series with greatly reduced no-load losses; Grade-1 energy efficiency | Core Loss Reduction | Amorphous-alloy SCBH series designed to significantly reduce no-load losses |
| Typical Applications | High-rise buildings; commercial complexes; hospitals; schools; rail transit; metro tunnels; data centers | New Energy Applications | PV and wind-power step-up applications; box-type substations; prefabricated E-houses |
| Industrial Applications | Industrial and mining plants; metallurgical systems; harmonic-load applications; dry-type rectifier transformers | Special Applications | Rectifier and earthing applications; indoor distribution systems; overseas EPC projects |
| Factory Acceptance Testing | Routine tests and type tests including partial-discharge and temperature-rise verification | Environmental-Fire Type Tests | C2/E2/F1 environmental and fire classification type tests available upon request |
| Short-Circuit Test | Excluded from FAT scope; witnessed testing by client or third-party inspectors available | Site Support | Installation guidance; commissioning supervision; post-commissioning performance verification |
| Warranty | Comprehensive product warranty; extended service agreement optional | Spare Parts Supply | Minimum 25-year spare-parts supply for key components |
| Technical Training | On-site or remote O&M training covering temperature-controller operation, winding inspection and harmonic-load operation | Quality System | ISO 9001; ISO 14001; ISO 45001 |
| Customization | Silicon-steel / amorphous-alloy options; F/H insulation class; on-load tap-changer; C2/E2/F1 grades; high-altitude and anti-corrosion enclosures | Frequency Options | 50Hz domestic version / 60Hz overseas export version |
| Technical Documentation | Electromagnetic-thermal simulation documents; full type-test reports; component certificates; material traceability documentation | ESG Documentation | LCA life-cycle-assessment documentation available upon request |