Air Insulated Switchgear

Let Us Show you what sets us apart

ais

Product Overview

Medium Voltage Air Insulated Switchgear

Air Insulated Switchgear for Reliable Power Transmission and Substation Applications

Medium Voltage Air Insulated Switchgear (AIS) is designed for electrical power distribution, circuit control and protection in utility substations, industrial facilities, commercial buildings and infrastructure projects.

Available in rated voltage levels of 12 kV, 17.5 kV and 24 kV, the switchgear features a metal-clad, compartmentalized construction with vacuum circuit breaker technology and an air-based insulation system.

The modular design provides flexible configurations for incoming feeders, outgoing feeders, bus couplers, metering and transformer protection. It supports reliable power distribution, electrical isolation and safe operation in medium-voltage power systems.

The switchgear can be configured according to project requirements, including rated current, short-circuit withstand capacity, busbar arrangement, protection functions and control requirements.

Air Insulated Switchgear Overview

  • Multiple Voltage Ratings: Available in 12 kV, 17.5 kV and 24 kV configurations.

  • Metal-Clad Construction: Compartmentalized metal-enclosed structure for functional separation of electrical components.

  • Vacuum Interruption Technology: Vacuum circuit breakers provide reliable switching and interruption of medium-voltage circuits.

  • Air-Based Insulation: Uses an air-based insulation and isolation design with cast resin insulated components.

  • High Current Capacity: Rated normal current up to 4000 A for 12 kV and 17.5 kV systems, and up to 2500 A for 24 kV systems.

  • Short-Circuit Withstand Capability: Available short-time withstand ratings up to 50 kA for 12 kV and 17.5 kV systems, and up to 31.5 kA for 24 kV systems.

  • Compartmentalized Design: Separate busbar, switching device and cable compartments.

  • Flexible System Configuration: Supports different feeder arrangements, protection functions and busbar configurations.

  • Advanced Protection Options: Compatible with protection relays, monitoring systems and optional remote operation functions.

Key Features

Compact and Space-Saving Design

The integrated modular structure reduces substation footprint and makes Hybrid GIS suitable for projects with limited installation space.

High Operational Reliability

Designed for dependable switching, isolation, and protection of high-voltage power transmission and distribution systems under specified operating conditions.

Modular and Flexible Configuration

Grounded metal enclosures protect internal components from external environmental influences and provide a controlled insulation environment.

Easy Inspection and Maintenance

The open-air equipment arrangement provides convenient visual inspection and access to individual components, subject to electrical safety requirements.

Wide Voltage Range

Available for various high-voltage and extra-high-voltage applications, with equipment ratings selected according to project requirements.

High Safety Standards

Can incorporate circuit breakers, disconnectors, earthing switches, protection relays, electrical interlocks, and other safety devices to support safe operation and maintenance.

Integrated Protection and Control

Compatible with protection relays, monitoring systems, substation automation, SCADA, and remote-control interfaces according to project specifications.

Indoor and Outdoor Applications

Depending on the design and enclosure configuration, GIS can be installed in indoor substations, outdoor substations, underground facilities, and space-constrained locations.

Environmentally Friendly Insulation

Uses atmospheric air as the primary insulation medium and does not require SF₆ gas for the air-insulated arrangement, reducing reliance on fluorinated insulating gases.

medium voltage air insulated switchgear
medium voltage air insulated switchgear application

Air Insulated Switchgear Technical Specifications

The following specifications are indicative reference ranges for AIS. Final ratings depend on the selected equipment, system voltage, manufacturer design, and project

Parameter

Specification

Product Type

Medium Voltage Air Insulated Switchgear (AIS)

Rated Voltage

12 / 17.5 / 24 kV

Frequency

50 / 60 Hz

Rated Current

630–4000 A (12 / 17.5 kV); 630–2500 A (24 kV)

Rated Breaking Current

25–50 kA (subject to voltage rating and VCB configuration)

Rated Short-Time Withstand Current

25–50 kA / 3 s (12 / 17.5 kV); 20–31.5 kA / 3 s (24 kV)

Rated Peak Withstand Current

63–130 kA (12 / 17.5 kV); 50–80 kA (24 kV)

Main Circuit Breaker

Vacuum Circuit Breaker (VCB)

Insulation Medium

Air Insulation / Cast Resin Insulated Components

Enclosure Type

Metal-Clad, Metal-Enclosed

Protection Degree

IP4X

Loss of Service Continuity Category

LSC2B

Partition Class

PM

Internal Arc Classification

IAC AFLR

Applicable Standards

IEC 62271 Series

Busbar Arrangement

Single Busbar / Double Busbar, subject to configuration

Electrical Parameters by Voltage

Parameter12 kV17.5 kV24 kV
Rated Voltage12 kV17.5 kV24 kV
Lightning Impulse Withstand Voltage75 kV95 kV125 kV
Power Frequency Withstand Voltage28 kV38 kV50 kV
Rated Frequency50 / 60 Hz50 / 60 Hz50 / 60 Hz
Rated Normal Current630–4000 A630–4000 A630–2500 A
Rated Short-Time Withstand Current25–50 kA25–50 kA20–31.5 kA
Short-Time Duration3 s3 s3 s
Rated Peak Withstand Current63–130 kA63–130 kA50–80 kA
Internal Arc ClassificationAFLR, up to 50 kA / 1 sAFLR, up to 50 kA / 1 sAFLR, up to 31.5 kA / 1 s

Note: Electrical ratings depend on the selected switchgear configuration. Maximum current, short-circuit withstand and internal arc ratings are not necessarily available simultaneously in every panel configuration. Final specifications should be confirmed against the approved technical documentation and applicable test reports.

Main Components

  • The switchgear consists of the following main functional components and electrical assemblies:

    Busbar Compartment

    Accommodates the main busbar system and associated connections. The busbar arrangement can be selected according to the power distribution design.

    Switching Device Compartment

    Houses the vacuum circuit breaker or other selected switching device. It provides switching, isolation and circuit protection functions.

    Cable Compartment

    Provides cable termination space and accommodates associated electrical components, including current transformers, voltage transformers and earthing switches.

    Main Electrical Components

    • Vacuum Circuit Breaker (VCB)

    • Main Busbar System

    • Current Transformer (CT)

    • Voltage Transformer (VT)

    • Earthing Switch

    • Protection and Control Relay

    • Cable Connection Terminals

    • Mechanical and Electrical Interlocking Devices

Technical Standards and Safety Features

The switchgear is designed with reference to the applicable IEC 62271 series standards for medium-voltage switchgear and controlgear.

Key technical characteristics include:

  • Metal-enclosed compartmentalized construction

  • Loss of Service Continuity Category LSC2B

  • Partition Class PM

  • IP4X enclosure protection

  • Internal Arc Classification AFLR, according to the selected electrical rating and tested configuration

  • Mechanical and electrical interlocking systems

  • Vacuum circuit breaker switching technology

  • Air-based insulation system

These characteristics are intended to support equipment protection, operational safety and maintenance accessibility.

Optional Configurations

Different electrical and control configurations can be selected according to project requirements.

Busbar and Switching Configurations

  • Single Busbar System

  • Double Busbar System

  • Vacuum Circuit Breaker

  • Vacuum Contactor

Measurement and Protection Components

  • Current Transformer (CT)

  • Voltage Transformer (VT)

  • Earthing Switch

  • Protection Relay

  • Metering and Measurement Units

Control and Monitoring Options

  • Remote Control and Monitoring

  • Electrical and Mechanical Interlocking

  • Temperature Monitoring System

  • Infrared Temperature Monitoring

  • Internal Arc Protection and Arc Channel Options

Customized Design

  • Customized Panel Dimensions

  • Customized Feeder Arrangements

  • Project-Specific Electrical Configurations

  • Customized Control and Protection Schemes

Optional functions and configurations are subject to the selected design and technical requirements.

The switchgear is designed with reference to the applicable IEC 62271 series standards for medium-voltage switchgear and controlgear.

Key technical characteristics include:

  • Metal-enclosed compartmentalized construction

  • Loss of Service Continuity Category LSC2B

  • Partition Class PM

  • IP4X enclosure protection

  • Internal Arc Classification AFLR, according to the selected electrical rating and tested configuration

  • Mechanical and electrical interlocking systems

  • Vacuum circuit breaker switching technology

  • Air-based insulation system

These characteristics are intended to support equipment protection, operational safety and maintenance accessibility.

Typical Applications

Medium Voltage Air Insulated Switchgear is suitable for power distribution, switching and protection in various applications.

Utility Substations

Used for medium-voltage power distribution, feeder control and transformer protection in utility substations.

Industrial Facilities

Provides power distribution and circuit protection for manufacturing plants, processing facilities and heavy industrial installations.

Power Generation Facilities

Supports medium-voltage distribution and auxiliary power systems in power generation projects.

Renewable Energy Projects

Suitable for electrical collection and distribution systems in solar and wind power installations.

Commercial Buildings and Infrastructure

Used in commercial complexes, transportation facilities and other infrastructure power distribution systems.

Data Centers

Supports medium-voltage power distribution and electrical protection for data center power infrastructure.

Related Products

Explore related medium-voltage electrical equipment and components:

  • Vacuum Circuit Breaker (VCB)

  • Current Transformer (CT)

  • Potential Transformer (PT / VT)

  • Protection Relay

  • Medium Voltage Switchgear Components

  • Power Distribution Equipment

Why Choose Our Air Insulated Switchgear

Flexible Product Solutions

Different equipment configurations, operating arrangements, and installation options can be provided according to application requirements.

Technical Documentation Support

Product specifications, drawings, and supporting documents can be provided according to the selected model and project requirements.

Application-Based Selection

Our team can review the intended application and technical requirements to help determine a suitable product configuration.

Project-Oriented Support

Our technical team can review project requirements and provide suitable equipment solutions for different power system applications.

Modular Equipment Design

The compartmentalized structure supports flexible panel arrangements and project-specific configurations.

Customized Switchgear Solutions

Busbar arrangements, feeder types, protection functions and control schemes can be adapted to different project requirements.

Request a Technical Proposal

Would you like to start a project with us?

Looking for a medium-voltage air insulated switchgear solution for your project?

Provide your rated voltage, rated current, short-circuit capacity, single-line diagram and application requirements. A suitable switchgear configuration can then be proposed according to your project specifications.

Contact our technical team for product information, technical documentation and a project quotation.

WHAT WE DO

CTSS Transformer Applications and Solutions

We design and manufacture liquid-filled power transformers and distribution transformers for a wide range of applications, including solar power, data centers, industrial facilities, and utility systems. With experienced engineers and advanced manufacturing capabilities, we provide customized transformer solutions and complex winding designs to meet the specific electrical and performance requirements of each project.

Power Utility

Power Utility

Thermal, nuclear, and large hydro power plants — generator step-up (GSU) duty.

images (2)

Solar & Wind Energy

Centralized wind and solar collection stations requiring bulk power step-up.

ctss mining transformer project

Mining

Steel mills, mines, data centers, and other high-power industrial facilities.

for ev charge

EV Charging Station

High-power electrical facilities requiring reliable transformer solutions and flexible configuration.

oil & gas 6.jpg

Oil & Gas

Demanding industrial facilities requiring reliable power supply and robust transformer performance.

bitcoin mining

Telecom & Data Center

High-power data centers requiring reliable transformer solutions for demanding electrical loads.