Air-core Reactor

Let Us Show you what sets us apart

Product Overview

Air-core Reactor

air core reactor 832
High-voltage rated voltage6kV / 10kV / 35kV / 66kV / 110kV; customizable
Low-voltage rated voltageNot applicable
Rated capacity50kvar ~ 120Mvar
Power Supply ModeSeries / shunt / filter / neutral earthing / motor starting reactor
Frequency50Hz; 60Hz customizable for overseas projects
Cooling TypeAN air natural cooling, dry type

Air-Core Reactor Technical Specifications

ParameterValueParameterValue
High-voltage rated voltage6kV / 10kV / 35kV / 66kV / 110kV; customizableLow-voltage rated voltageNot applicable
Rated capacity50kvar ~ 120MvarPower Supply ModeSeries / shunt / filter / neutral earthing / motor starting reactor
Frequency50Hz; 60Hz customizable for overseas projectsCooling TypeAN air natural cooling, dry type
Product TypeDry-type air-core reactorReactance RateSeries reactor: 0.1% ~ 18%; shunt reactor customized on request
Insulation LevelCompliant with IEC 60076-6 and GB/T 1094.6InstallationIndoor / outdoor; vertical stacking or horizontal layout
Ambient Conditions-40°C ~ +40°C; high altitude, coastal salt spray and extreme cold versions availableInsulation MediumEpoxy glass fibre dry encapsulation; oil-free
Inductance CharacteristicNo iron core saturation; high inductance linearity; stable inductance under harmonic conditionsPartial Discharge<= 10pC at 1.1 x rated voltage
Noise LevelTypical 62dB(A) at 1m; low-noise version availableShort-Circuit WithstandDesigned and validated per IEC 60076-5 with dynamic force margin > 1.3 x calculated values
Thermal PerformanceTemperature rise complies with IEC/GB standards; sufficient thermal margin under harmonic loadDesign Life>= 30 years under normal indoor / outdoor operating conditions
Conductor MaterialMulti-strand parallel oxygen-free aluminium; copper optionalConductor InsulationFilm insulation on individual strands with conductor transposition
Encapsulation SystemGlass fibre + epoxy resin vacuum impregnated encapsulation; integral curingInsulation StructureMulti-layer encapsulation with turn-to-turn and layer insulation redundancy
Support InsulatorsHigh-strength epoxy insulators; hydrophobic and anti-pollutionAnti-Corrosion GradeC3, C4, C5, CX-H
Standard AccessoriesSupport insulators, earth terminals, corona shields and rain hoodsTemperature MonitoringFibre-optic temperature online monitoring optional
Design MethodElectromagnetic-thermal-flow-structural multi-physics coupled designElectromagnetic Simulation3D FEM; inductance linearity; harmonic loss; turn-to-turn electric field; external magnetic field
Mechanical SimulationANSYS structural simulation; short-circuit electrodynamic force; encapsulation and support strengthThermal-Flow SimulationCFD natural convection simulation; steady-state and harmonic temperature rise prediction
Insulation CoordinationTurn-to-turn and layer insulation electric field simulation; lightning and switching impulse verificationSeismic QualificationIEEE 693 compliance available as an option
Typical Model35kV, 12000kvar, 6% dry-type air-core series reactorReference CoolingAN air natural cooling
Reference InstallationOutdoor substation installationReference Anti-CorrosionC3, C4, C5, CX-H
Applicable StandardsIEC 60076-6; GB/T 1094.6; GB/T 25076Export StandardsIEEE C57.16 optional; IEEE 693 optional; RoHS and REACH
Quality SystemISO 9001; ISO 14001; ISO 45001Material TraceabilityKey materials compliant with IEC/GB requirements with full traceability
Typical ApplicationsPV/wind power collection substations; power grid substations; rail transit; industrial VFD; arc furnace systemsApplication FunctionsReactive power compensation; harmonic filtering; current limiting; neutral earthing; series resonance
Factory Acceptance TestingInductance measurement; resistance; loss; partial discharge; dielectric withstand testsThird-Party TestingShort-circuit testing by professional authorized third-party laboratories
Site SupportInstallation guidance; lifting supervision; pre-commissioning inspection; commissioning supportWarrantyComprehensive product warranty; extended service agreement optional
Spare Parts SupplyMinimum 25-year spare-parts supply for key componentsTechnical TrainingOn-site or remote O&M training covering magnetic field, heating and maintenance
CustomizationSeries / shunt / filter / neutral earthing reactors; adjustable reactance rateEnvironmental OptionsHigh altitude; coastal salt spray; extreme cold; low-noise versions
ESG DocumentationLCA life-cycle assessment documentation available upon requestTechnical DocumentationSimulation reports; type-test reports; material certificates; material traceability documents
standard accessories 修改0916

Protection & Accessories

Reliable Protection System and Flexible Accessories

Our Pad Mounted Transformers are equipped with reliable protection devices and accessories to ensure safe operation in underground distribution systems and utility applications.

Standard Accessories

HV/LV Bushings

Reliable medium voltage connection with excellent insulation performance.

Oil Level Gauge

Easy monitoring of insulating oil level for maintenance.

 

Pressure Relief Device

Improves transformer safety under abnormal conditions.

Drain Valve

Convenient oil draining and maintenance operation.

Tap Changer

Off-circuit Tap Changer (OCTC), ±2 × 2.5%

Nameplate

Provides complete transformer rating and technical information.

other asserssories

Optional Accessories

Temperature Indicator

Monitors transformer operating temperature for reliability.

Remote Monitoring System

Supports smart grid and remote transformer condition monitoring.

Surge Arrester

Protects pad mounted transformers against lightning and voltage surges.

Key Features of Transformers

Key Benefits:

  • Enhanced operator and public safety
  • No exposed high-voltage components
  • Suitable for underground distribution systems
  • Reliable operation in outdoor environments

Key Benefits:

  • Weather-resistant construction
  • Corrosion-resistant surface treatment
  • Secure locking compartment
  • Suitable for public and utility applications

Key Benefits:

  • Space-saving installation
  • Low-profile outdoor design
  • Easy inspection and maintenance
  • Ideal alternative to overhead distribution systems

Available Configurations:

  • Loop feed distribution system
  • Radial feed distribution system
  • Dead-front cable connection
  • Customized MV and LV connection arrangements

Available protection and accessories include:

  • High voltage fuses
  • Current limiting fuses
  • Load break switches
  • Surge arresters
  • Pressure relief devices
  • Temperature monitoring systems

These protection solutions help ensure safe operation under different load and fault conditions.

Key Benefits:

  • Low no-load losses
  • High energy efficiency
  • Excellent thermal performance
  • Long operational lifetime
strict quality control and transformer testing 1

Manufacturing & Testing

Strict Quality Control and Transformer Testing

Every Pad Mounted Transformer undergoes comprehensive testing to ensure high reliability, safety and long service life according to international standards.

Routine Tests

Transformer Ratio Test

Ensures accurate voltage transformation performance.

Winding Resistance Test

Verifies winding quality and electrical performance.

 

No-Load Loss Test

Checks transformer core efficiency and energy performance.

No-Load Loss Test

Confirms transformer rated efficiency under operating conditions.

Impedance Test

Ensures correct electrical characteristics and system compatibility.

Dielectric Test

Verifies insulation strength and operational safety.

special testing

Special Tests

Temperature Rise Test

Validates thermal performance and cooling capability.

Lightning Impulse Test

Tests insulation capability against surge conditions.

Partial Discharge Test

Ensures insulation quality and long-term reliability.

Everything We Do Is At A High Standard

Would you like to start a project with us?

WHAT WE DO

CTSS Transformer Applications and Solutions

We design and manufacture liquid-filled power transformers and distribution transformers for a wide range of applications, including solar power, data centers, industrial facilities, and utility systems. With experienced engineers and advanced manufacturing capabilities, we provide customized transformer solutions and complex winding designs to meet the specific electrical and performance requirements of each project.

images (4)

Power Utility

Thermal, nuclear, and large hydro power plants — generator step-up (GSU) duty.

images (2)

Solar & Wind Energy

Centralized wind and solar collection stations requiring bulk power step-up.

usine vue aerienne 04(1)

Mining

Steel mills, mines, data centers, and other high-power industrial facilities.

for ev charge

EV Charging Station

High-power electrical facilities requiring reliable transformer solutions and flexible configuration.

oil & gas 6.jpg

Oil & Gas

Demanding industrial facilities requiring reliable power supply and robust transformer performance.

bitcoin mining

Telecom & Data Center

High-power data centers requiring reliable transformer solutions for demanding electrical loads.