WHO WE ARE
Top Providers of Commercial & Industrial Transformers
CTSS offers a comprehensive selection of commercial and industrial transformers. Our company designs, manufactures, and supplies transformers with an annual production capacity of 36 million kVA and voltage levels up to 330kV, with 500kV available upon request.
Expert design engineers support all of our power transformer projects to deliver solutions that meet your specific needs. Our quality management system is certified to GB/T 19001-2016 / ISO 9001:2015, with UL/cUL certification and SGS compliance verification supporting our commitment to quality, safety, and reliable transformer solutions.

Electric Furnace Transformer
| Primary Voltage | Customized according to furnace requirements |
|---|---|
| Secondary Voltage | Commonly 6 kV, 10 kV, 11 kV, 20 kV, 33 kV, 35 kV, 66 kV or higher |
| Rated capacity | Approximately 1 MVA to 200 MVA or customized |
| Frequency | 50 Hz / 60 Hz |
| Cooling Type | ONAN / ONAF / OFAF / ODAF / OFWF |
| Insulation Medium | Mineral Oil / Alternative Insulating Liquid |

Neutral Grounding Resistor NGR
| Primary Voltage | 0.4 kV–110 kV applicable voltage range; confirm the system-specific rated voltage. |
|---|---|
| Secondary Voltage | Resistor rating unspecified; confirm optional grounding transformer. |
| Rated capacity | Project-specific; Not specified; subject to confirmation. |
| Frequency | Not specified; confirm with the manufacturer. |
| Cooling Type | Airflow-based heat dissipation through the resistor enclosure; confirm the final configuration. |
| Insulation Medium | Air insulation for the resistor assembly; confirm the final design |

Traction Transformer
| Primary Voltage | 110kV / 220kV, other voltages customizable |
|---|---|
| Secondary Voltage | 27.5kV / 2 x 27.5kV |
| Rated capacity | 10MVA - 63MVA, larger capacities customizable |
| Frequency | 50Hz, 60Hz customizable for overseas projects |
| Cooling Type | ONAN / ONAF / OFAF forced-oil-forced-air cooling |
| Insulation Medium | Mineral insulating oil, high-fire-point biodegradable ester fluid optional |

VV and VI transformer
| Primary Voltage | Up to 35 kV |
|---|---|
| Secondary Voltage | Customized according to project requirements |
| Rated capacity | 10 kVA - 5000 kVA per single-phase unit; combined three-phase capacity available |
| Frequency | Not specified in the source document |
| Cooling Type | ONAN / ONAF for oil-immersed type; AN / AF for dry-type |
| Insulation Medium | Oil-immersed or dry-type |

Scott Transformer
| Primary Voltage | 10kV / 35kV / 110kV; customizable |
|---|---|
| Secondary Voltage | Customized for traction / arc furnace loads; typical 2 x 27.5kV |
| Rated capacity | 1MVA - 120MVA |
| Frequency | 50Hz; 60Hz customizable for overseas projects |
| Cooling Type | Oil-immersed: ONAN / ONAF / OFAF; dry-type: AN / AF |
| Insulation Medium | Mineral oil or high-fire-point ester oil for oil-immersed type; dry-type epoxy encapsulation |

Rectifier Transformer
| Primary Voltage | 3kV - 110kV; higher voltage available upon custom request |
|---|---|
| Secondary Voltage | 0.4kV - 3.5kV valve-side voltage; customized for rectifier bridge applications |
| Rated capacity | 500kVA - 50MVA; larger capacity available upon custom design |
| Frequency | 50Hz / 60Hz; dual-frequency design available |
| Cooling Type | ONAN / ONAF / OFAF for oil-immersed type; AN / AF for dry-type |
| Insulation Medium | Mineral oil or biodegradable ester fluid for oil-immersed type; F/H-class epoxy casting for dry-type |