3 phase oil immersed distribution transformer 11kv

11kV Three Phase Oil Immersed Distribution Transformer

Primary Voltage11 kV
Secondary Voltage0.4 kV
Rated capacity30–2500 kVA
Frequency50 Hz / 60 Hz
Cooling TypeONAN
Insulation MediumMineral Transformer Oil
single phase pad mounted transformer up to 34.5 kv

Single Phase Pad Mounted Transformer Up to 34.5 kV

Primary Voltage34.5 kV
Secondary Voltage120 / 240 V
Rated capacity100 / 250 kVA
Frequency50 / 60 Hz
Cooling TypeONAN
Insulation MediumMineral Oil
ctss electric furnace transformer special transformer tr

Electric Furnace Transformer

Primary VoltageCustomized according to furnace requirements
Secondary VoltageCommonly 6 kV, 10 kV, 11 kV, 20 kV, 33 kV, 35 kV, 66 kV or higher
Rated capacityApproximately 1 MVA to 200 MVA or customized
Frequency50 Hz / 60 Hz
Cooling TypeONAN / ONAF / OFAF / ODAF / OFWF
Insulation MediumMineral Oil / Alternative Insulating Liquid
接地电

Neutral Grounding Resistor NGR

Primary Voltage0.4 kV–110 kV applicable voltage range; confirm the system-specific rated voltage.
Secondary VoltageResistor rating unspecified; confirm optional grounding transformer.
Rated capacityProject-specific; Not specified; subject to confirmation.
FrequencyNot specified; confirm with the manufacturer.
Cooling TypeAirflow-based heat dissipation through the resistor enclosure; confirm the final configuration.
Insulation MediumAir insulation for the resistor assembly; confirm the final design
vv connection traction transformer

Traction Transformer

Primary Voltage110kV / 220kV, other voltages customizable
Secondary Voltage27.5kV / 2 x 27.5kV
Rated capacity10MVA - 63MVA, larger capacities customizable
Frequency50Hz, 60Hz customizable for overseas projects
Cooling TypeONAN / ONAF / OFAF forced-oil-forced-air cooling
Insulation MediumMineral insulating oil, high-fire-point biodegradable ester fluid optional
air core reactor 832

Air-core Reactor

Primary Voltage6kV / 10kV / 35kV / 66kV / 110kV; customizable
Secondary VoltageNot applicable
Rated capacity50kvar ~ 120Mvar
Frequency50Hz; 60Hz customizable for overseas projects
Cooling TypeAN air natural cooling, dry type
Insulation MediumEpoxy glass fibre dry encapsulation; oil-free
sf6 circuit breaker 40.5kv

HV AIS Circuit Breaker

Rated Voltage40.5 kV
Rated Current1600 / 2000 A
Rated Breaking Current20 / 25 / 31.5 kA
Frequency50 Hz
Insulation MediumVacuum
12kv sf₆ free ring main unit (rmu) – single panel

SF6-Free Ring Main Unit 12kV

Rated Voltage12 kV
Rated Current630–1250 A
Rated Breaking Current20 / 25 kA*
Frequency50 Hz
Insulation MediumSF₆-Free Clean Air / Nitrogen
sf6 circuit beaker tr 1

SF6 Circuit Breaker 35kV-550Kv

Rated Voltage35 kV / 72.5 kV / 126 KV / 145 kV / 252 kV / 550 kV
Rated Current1600 A / 2000 A / 3150 A / 4000 A / 5000 A
Rated Breaking Current20 KA / 25 KA / 31.5 kA / 50 KA / 40 KA / 63 kA
Frequency50 Hz
Insulation MediumSF₆ Gas
ais

Air Insulated Switchgear

Rated Voltage12 / 17.5 / 24 kV
Rated Current630–4000 A (12 / 17.5 kV); 630–2500 A (24 kV)
Rated Breaking Current25–50 kA (subject to voltage rating and VCB configuration)
Frequency50 / 60 Hz
Insulation MediumAir Insulation / Cast Resin Insulated Components
gis

SF6 Gas Insulated Switchgear

Rated Voltage72.5 kV to 550 kV and above, depending on product series
Rated CurrentCommonly 1,250 A to 4,000 A or higher, depending on design
Rated Breaking CurrentCommonly 25 kA to 63 kA, depending on voltage class and design
Frequency50 Hz / 60 Hz
Insulation MediumSF₆ gas
hgis 主图 tr

Hybrid (SF6) GIS

Rated Voltage145 kV (reference model)
Rated CurrentUp to 3150 A (reference model)
Rated Breaking Current25 kA, depending on model
Frequency50 / 60 Hz
Insulation MediumSF6 Gas
gis 主图 tr

High-Voltage (SF6) GIS

Rated Voltage72.5kV / 126kV / 145kV / 252kV / 420kV / 550kV
Rated Current1250A – 5000A
Rated Breaking Current31.5kA – 63kA
Frequency50Hz / 60Hz
Insulation MediumSF6 Gas
high voltage insulator tr 1

Insulator

Rated VoltageConfirm by model
Frequency50 / 60 Hz, confirm by model
Insulation MediumPorcelain / Composite Silicone Rubber, confirm by model
surge arrester

Surge Arrester

Rated VoltageAvailable according to system requirements
Frequency50 Hz / 60 Hz, subject to design
Insulation MediumAir