CTSS Power Transformers provides transformer solutions for a wide range of electrical power applications, covering low-, medium-, and high-voltage systems. Explore our frequently asked questions about transformer products, technical specifications, project applications, quality requirements, and quotations.
Whether you are planning an industrial power system, a substation, a renewable energy project, or a power distribution network, this FAQ can help you understand key transformer selection considerations and prepare for your project inquiry.
01.
Company & Manufacturing Capabilities
CTSS Power Transformers provides transformer solutions for a wide range of electrical power applications, from low-voltage power distribution to medium- and high-voltage power systems.
Our product offering includes power transformers, distribution transformers, oil-immersed transformers, dry-type transformers, and other transformer solutions designed to meet different electrical and project requirements.
Depending on the application, transformer selection may involve rated capacity, voltage ratio, winding configuration, impedance, cooling method, installation environment, and applicable technical standards.
Contact CTSS to discuss your project requirements and identify a suitable transformer solution.
CTSS provides transformer solutions for low-, medium-, and high-voltage applications. The appropriate voltage range depends on the transformer type, rated capacity, electrical configuration, and project requirements.
Our solutions can support different stages of power conversion and distribution, from supplying low-voltage equipment to connecting medium- and high-voltage networks.
When requesting a quotation, please specify the primary voltage, secondary voltage, rated frequency, transformer capacity, and intended application. For exact voltage ratings and product availability, contact CTSS with your project specifications.
Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo. Proin gravida nibh vel velit auctor aliquet. Aenean sollicitudin, lorem quis bibendum auctor, nisi elit consequat ipsum, nec sagittis sem nibh id elit. Duis sed odio sit amet nibh vulputate cursus a sit amet mauris. Morbi accumsan ipsum velit.
Nam nec tellus a odio tincidunt auctor a ornare odio. Sed non mauris vitae erat consequat auctor eu in elit. Class aptent taciti sociosqu ad litora torquent per conubia nostra, per inceptos himenaeos. Mauris in erat justo.
Transformer solutions are essential in power generation, transmission, distribution, and industrial electrical systems.
CTSS transformer solutions can be evaluated for applications such as:
Power utilities and electrical grids: Power transmission, distribution networks, and grid infrastructure.
Substations and industrial power systems: Voltage transformation for electrical distribution and industrial loads.
Renewable energy: Solar and wind power generation and grid interconnection.
Manufacturing and industrial facilities: Power supply for production lines, machinery, and plant electrical systems.
Commercial and infrastructure projects: Electrical systems for buildings, facilities, and infrastructure developments.
Each project has different electrical and environmental requirements. Transformer specifications should be selected according to the intended application, system design, and applicable standards.

02.
Transformer Products & Applications
Oil-immersed and dry-type transformers differ mainly in their insulation and cooling arrangements.
Oil-immersed transformers use an insulating liquid to provide electrical insulation and transfer heat away from the core and windings. They are widely used in utility networks, substations, industrial power systems, and many outdoor applications.
Dry-type transformers use solid insulation systems and air-based or other specified cooling arrangements instead of conventional insulating oil. They are often considered for indoor installations and locations where fire safety, environmental conditions, and maintenance requirements are important considerations.
The right choice depends on installation location, load profile, fire protection requirements, environmental conditions, available space, and lifecycle cost.
Renewable energy projects may require different transformer types depending on the generation technology, system architecture, voltage level, and grid connection requirements.
In solar power systems, transformers may increase voltage from inverter output to the collection or grid-interconnection voltage. Wind power projects may require transformers within individual turbines, collection networks, substations, or grid connection systems.
Important selection factors include rated power, voltage ratio, inverter or generator characteristics, harmonic content, insulation, cooling, ambient temperature, and grid connection requirements.
Providing the inverter or generator specifications, project single-line diagram, and grid connection requirements can help CTSS assess a suitable transformer solution.
Substations and industrial power systems use transformers to transfer electrical energy between voltage levels and distribute power throughout a network.
Depending on the system design, applications may require power transformers, distribution transformers, oil-immersed transformers, dry-type transformers, or other specialized configurations.
For substations, selection factors include incoming and outgoing voltages, rated capacity, load characteristics, fault levels, cooling requirements, and protection schemes.
Industrial facilities may also need to consider motor starting, load fluctuations, harmonic distortion, continuous operating conditions, and future capacity expansion.
CTSS can review your project’s electrical requirements to help identify a suitable transformer configuration.

03.
Technical Specifications & Selection
Choosing the right transformer requires matching the equipment to the expected load and ensuring compatibility with the electrical system.
Key selection factors include:
Load demand: Calculate the expected load in kW or kVA and consider the power factor.
Rated capacity: Allow for appropriate operating margin and anticipated future expansion.
Primary and secondary voltages: Confirm the incoming and required outgoing voltage levels.
Frequency and phase: Specify the system frequency and whether single-phase or three-phase equipment is required.
Operating conditions: Consider ambient temperature, installation location, and load variation.
Impedance and protection: Confirm compatibility with the system’s fault levels and protection requirements.
Applicable standards: Identify the standards and project specifications the transformer must satisfy.
For a more accurate recommendation, provide CTSS with your load requirements, voltage levels, single-line diagram, and intended application.
Transformer cooling methods remove heat generated by electrical losses and help keep the transformer within its permitted operating temperature range.
Common cooling arrangements include:
ONAN: Oil Natural, Air Natural. Oil and surrounding air circulate naturally.
ONAF: Oil Natural, Air Forced. Oil circulates naturally while fans provide forced-air cooling.
Dry-type air cooling: Heat is dissipated through natural or forced air circulation, depending on the design.
The appropriate cooling method depends on transformer construction, rated capacity, load profile, ambient temperature, installation conditions, and operating requirements.
Cooling arrangements vary by transformer type and applicable standards. The selected configuration should be confirmed in the technical specification.
Transformer standards help define requirements for design, ratings, performance, testing, safety, and other technical characteristics.
Depending on the project and destination market, relevant standards may include the IEC 60076 series or applicable IEEE/ANSI C57 standards. Other national, regional, utility, or project-specific requirements may also apply.
Before ordering, customers should confirm:
Required design and manufacturing standards.
Rated capacity, voltage ratio, and frequency.
Winding connection and vector group.
Impedance and permitted losses.
Insulation levels and temperature-rise limits.
Cooling method and installation conditions.
Routine tests, special tests, and documentation requirements.
Applicable certification or local regulatory requirements.
The applicable standard should be agreed upon before manufacturing. Compliance should be confirmed for the specific product and project.

04.
Quality, Delivery & Project Support
Transformer testing helps verify that the equipment conforms to its agreed technical specifications and applicable requirements.
Depending on the transformer type, applicable standard, and purchase specification, testing may include winding resistance measurement, voltage-ratio verification, polarity or vector-group checks, insulation-related tests, no-load loss and current measurements, load-loss and impedance measurements, and dielectric tests.
Additional or special tests may be required for certain projects.
The exact test scope depends on the transformer design, applicable standard, and contractual requirements. Customers should specify any required inspection, witness testing, test reports, or third-party inspection before production begins.
Providing complete technical information helps reduce clarification time and allows the manufacturer to assess the project more accurately.
For a transformer quotation, please provide as much of the following information as possible:
Rated capacity in kVA or MVA.
Primary and secondary voltage ratings.
Rated frequency and number of phases.
Winding connection or vector group, if specified.
Impedance requirements, if specified.
Cooling method and insulation requirements.
Applicable standards and project specifications.
Indoor or outdoor installation conditions.
Required accessories and monitoring or protection devices.
Quantity, delivery destination, and target delivery date.
Single-line diagrams or technical documents, if available.
If some details are not yet finalized, you can still contact CTSS with your basic project requirements. Our team can identify the key information needed to proceed with a technical review.
Transformer standards help define requirements for design, ratings, performance, testing, safety, and other technical characteristics.
Depending on the project and destination market, relevant standards may include the IEC 60076 series or applicable IEEE/ANSI C57 standards. Other national, regional, utility, or project-specific requirements may also apply.
Before ordering, customers should confirm:
Required design and manufacturing standards.
Rated capacity, voltage ratio, and frequency.
Winding connection and vector group.
Impedance and permitted losses.
Insulation levels and temperature-rise limits.
Cooling method and installation conditions.
Routine tests, special tests, and documentation requirements.
Applicable certification or local regulatory requirements.
The applicable standard should be agreed upon before manufacturing. Compliance should be confirmed for the specific product and project.
To request a transformer quotation, contact CTSS through our website and share your project requirements.
For a faster technical review, include the transformer capacity, primary and secondary voltages, frequency, intended application, applicable standards, quantity, and delivery destination. Drawings or a project specification document are also helpful when available.
If your project requires a customized transformer or covers multiple voltage levels, describe the overall system requirements so that the proposed solution can be evaluated in context.
Visit our Contact page to submit your inquiry:
Contact CTSS Power Transformers: https://china-power-transformer.com/contact/
Explore our products: https://china-power-transformer.com/products/
Need a Transformer Solution for Your Project?
CTSS Power Transformers supports transformer inquiries across low-, medium-, and high-voltage applications. Share your technical requirements, project specifications, or equipment schedule with our team.
Contact us to discuss your application and request a quotation.
Get in Touch: https://china-power-transformer.com/contact/
Explore Our Products: https://china-power-transformer.com/products/

Request A Quote Today
REACH US
M: +86 138 198 98306
E: 14F, EBB Plaza, CBD, Yinzhou, Ningbo, China
☎ +86 574 8300 8192