Yaouré Gold Project
33MVA Power Transformer
High-voltage transformer solution for gold mining power infrastructure
Project Overview
CTSS for Yaouré Gold Project
The Yaouré Gold Project represents a demanding mining application where reliable electrical infrastructure is essential for supporting mineral processing, plant operations, and auxiliary electrical systems. A high-capacity power transformer provides the interface between the high-voltage supply network and the medium-voltage distribution system serving the mine.
The SFZ-33000/90 oil-immersed power transformer is specified for a voltage ratio of 90/11.5 kV, with a rated capacity of 25 MVA under ONAN cooling and 33 MVA under ONAF cooling. This dual cooling arrangement provides different rated operating capacities according to the specified cooling mode.
For mining power supply systems, transformer selection must consider load demand, voltage requirements, cooling conditions, site environment, and the electrical characteristics of the downstream network.
CTSS supplied a 33 MVA power transformer for the Yaouré Gold Project, featuring 90/11.5 kV voltage and ONAN/ONAF cooling.

Project Overview
CTSS Transformer Specifications
The SFZ-33000/90 power transformer features a three-phase configuration and a rated frequency of 50 Hz. Its 90 kV high-voltage side and 11.5 kV medium-voltage side are intended for the specified high-voltage-to-medium-voltage transformation arrangement.
The transformer has two stated cooling ratings: 25 MVA with ONAN cooling and 33 MVA with ONAF cooling. ONAN refers to oil natural, air natural cooling, while ONAF refers to oil natural, air forced cooling. The applicable capacity depends on the cooling mode and the approved operating conditions.
The specified YNyn0+d connection symbol identifies the winding connection arrangement. The installation altitude is specified as 1,000 meters. Final installation and operating requirements should be checked against the approved transformer drawings, nameplate, and project specifications.
33 MVA Power Transformer,
33000 kVA Transformer,
90/11.5 kV Transformer,
Yaouré Gold Project,
Gold Mine Power Supply,
Mining Transformer,
Oil-Immersed Power Transformer

Project Field | Details |
| Project Title | 33 MVA Power Transformer for Yaouré Gold Project |
| Project Name | Yaouré Gold Project |
| Equipment Type | Oil-Immersed Power Transformer |
| Transformer Model | SFZ-33000/90 |
| Rated Power | 25/33 MVA (ONAN/ONAF) |
| Rated Voltage | 90/11.5 kV |
| Number of Phases | Three Phase |
| Rated Frequency | 50 Hz |
| Cooling Method | ONAN/ONAF |
| Connection Symbol | YNyn0+d |
| Installation Altitude | 1,000 m |
| Manufacturer | CTSS POWER TRANSFORMER |
Application in Gold Mine Power Supply Systems
Gold mining operations rely on stable electrical power for processing plants, material handling systems, pumping equipment, ventilation, workshops, and other supporting facilities. Depending on the mine’s electrical design, a main power transformer can connect the incoming high-voltage supply to a medium-voltage distribution network.
A 90/11.5 kV transformer configuration can support this interface where the voltage levels match the mine’s approved power system design. The downstream 11.5 kV network can then distribute power to appropriately rated substations, motors, and other electrical loads.
The 25/33 MVA ONAN/ONAF rating provides two specified capacity levels under different cooling arrangements. Engineers should verify the expected load profile, ambient conditions, cooling equipment requirements, protection coordination, and allowable operating limits before finalizing the transformer selection.
Transformer Design Considerations for Mining Applications
Mining environments can impose demanding operating requirements on electrical equipment. A suitable power transformer specification should account for the following factors:
Load demand: Assess continuous loads, starting currents, load variations, and anticipated future expansion.
Voltage compatibility: Confirm that the transformer voltage ratio matches the incoming supply and the downstream distribution system.
Cooling performance: Verify the required ONAN and ONAF operating conditions and the availability of auxiliary cooling equipment.
Protection and monitoring: Define appropriate transformer protection, temperature monitoring, alarms, and trip arrangements in accordance with the project design.
Site conditions: Consider altitude, ambient temperature, dust exposure, installation layout, and maintenance access.
Applicable standards: Confirm the required IEC or other project-specific standards and acceptance tests.
These considerations help ensure that the selected transformer is aligned with the mine’s electrical requirements and long-term operating needs.
CTSS Power Transformer Solutions for Mining Applications
CTSS POWER TRANSFORMER provides power transformer solutions for industrial power distribution, utility infrastructure, and demanding electrical applications. Transformer configurations can be evaluated according to project-specific requirements, including rated capacity, voltage ratio, winding connection, cooling method, installation conditions, and applicable technical standards.
For gold mining and other heavy industrial applications, selecting the correct transformer requires coordination between the electrical load assessment, substation design, protection system, and equipment specification.
Contact CTSS POWER TRANSFORMER to discuss a customized power transformer solution for your mining or industrial power supply project.
Yaouré Gold Project 33MVA Power Transformer
The Yaouré Gold Project is a major gold mining operation in central Côte d’Ivoire, located about 40 km northwest of Yamoussoukro. Owned and operated by Perseus Mining, the site features both open-pit mining and CMA Underground—Côte d’Ivoire’s first mechanized underground gold mine, which began initial stoping in April 2026. Key Project Details • Location: Central Côte d’Ivoire
F.A.Q.
Supporting Subheading
The specified capacity is 25 MVA under ONAN cooling and 33 MVA under ONAF cooling. The 33 MVA rating is equivalent to 33,000 kVA.
It indicates the transformer’s specified high-voltage and medium-voltage ratings: 90 kV and 11.5 kV, respectively.
requirements.
ONAN uses natural oil circulation and natural air cooling. ONAF uses natural oil circulation with forced air cooling. The stated transformer ratings differ according to the specified cooling mode.
Power transformers connect supply networks to the voltage levels required by a mine’s electrical distribution system. They help deliver power to processing facilities and other industrial loads when correctly specified for the system.
Important information includes the required capacity, primary and secondary voltages, load profile, frequency, winding connection, cooling method, installation conditions, protection requirements, and applicable technical standards.